MONITORING THE BEAM F ’ CXJTlON IN THE SLC JNTERACTJON REGION

نویسندگان

  • G. B. Bowden
  • G. J. Oxoby
  • J.-L. Pellegrin
  • M. C. Ross
چکیده

The Stanford Linear Collider requires special Beam Position Monitors near the Interaction Point (JP) to bring the two beams (e+ and e-) into collision. These beams pass through two monitors on each side of the JP with a short time separation (about 20 and SOns). The mechanics of the monitors as well as the electronics will be described. Jn order to bring beams of several microns diameter into collision at the JP, these monitors measure beam deflection induced by the presence of the opposite beam.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precise System Stabilization at Slc Using Dither Techniques

M. C. Ross, L. Hendrickson, T. Himel, E. Miller Stanford Linear Accelerator Center Stanford, California 94309 Abstract A data acquisition method has been developed at the SLAC Linear Collider (SLC) that provides accurate beam parameter information using sub-tolerance xcitation and synchronized detection. This is being applied to several SLC sub-systems to provide high speed feedback on beam par...

متن کامل

Beam-beam Deflections as an Interaction Point Diagnostic for the Slc*

A technique is described for non-destructive measurement and monitoring of the steering offset of the electron and positron beams at the interaction point of the SLC, based on using stripline beam-position monitors to measure the centroid of one beam as it is deflected by the opposing beam. This technique is also expected to provide diagnostic information related to the spot rise of the micron-...

متن کامل

Beam-beam Simulations with Non-gaussian Distributions for Slc and Slc-2000

Due to various upstream beam manipulations, the longitudinal bunch shape at the interaction point of the Stanford Linear Collider (SLC) is highly non-Gaussian. In this paper, we report beam-beam simulations with realistic longitudinal bunch shapes for the present SLC parameters and for the SLC-2000 luminosity upgrade. The simulation results allow us to estimate the luminosity enhancement due to...

متن کامل

Beam-based Monitoring of the Slc Linac Optics with a Diagnostic Pulse

The beam optics in a linear accelerator may be changed significantly by variations in the energy and energy spread profile along the linac. In particular, diurnal temperature swings in the SLC klystron gallery perturb the phase and amplitude of the accelerating RF fields. If such changes are not correctly characterized, the resulting errors will cause phase advance differences in the beam optic...

متن کامل

Thermo-Electro Mechanical Impedance based Structural Health Monitoring: Euler- Bernoulli Beam Modeling

In recent years, impedance measurement method by piezoelectric (PZT) wafer activesensor (PWAS) has been widely adopted for non-destructive evaluation (NDE). In this method, theelectrical impedance of a bonded PWAS is used to detect a structural defect. The electro-mechanicalcoupling of PZT materials constructs the original principle of this method. Accordingly, the electricalimpedance of PWAS c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1987