Ultrasound guidance for internal jugular vein cannulation: Continuing Professional Development.

نویسندگان

  • Christian Ayoub
  • Catherine Lavallée
  • André Denault
چکیده

PURPOSE The objective of this continuing professional development module is to describe the role of ultrasound for central venous catheterization and to specify its benefits and limitations. Although ultrasound techniques are useful for all central venous access sites, the focus of this module is on the internal jugular vein approach. PRINCIPAL FINDINGS In recent years, several studies were published on the benefits of ultrasound use for central venous catheterization. This technique has evolved rapidly due to improvements in the equipment and technology available. Ultrasound helps to detect the anatomical variants of the internal jugular vein. The typical anterolateral position of the internal jugular vein with respect to the carotid is found in only 9-92% of cases. Ultrasound guidance reduces the rate of mechanical, infectious, and thrombotic complications by 57%, and it also reduces the failure rate by 86%. Cost-benefit analyses show that the cost of ultrasound equipment is compensated by the decrease in the expenses associated with the treatment of complications. In this article, we will review the history of ultrasound guidance as well as the reasons that account for its superiority over the classical anatomical landmark technique. We will describe the equipment needed for central venous catheterization as well as the various methods to visualize with ultrasound. CONCLUSION To improve patient safety, we recommend the use of ultrasound for central venous catheterization using the internal jugular approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Biplane Ultrasound Probe for Real-Time Visualization and Cannulation of the Internal Jugular Vein

Ultrasound guidance is recommended for cannulation of the internal jugular vein. Use of ultrasound allows you to identify relevant anatomy and possible anatomical anomalies. The most common approach is performed while visualizing the vein transversely and inserting the needle out of plane to the probe. With this approach needle tip visualization may be difficult. We report the use of a new bipl...

متن کامل

Accidental arterial puncture during right internal jugular vein cannulation in cardiac surgical patients

BACKGROUND The primary aim of this study was to compare the incidence of accidental arterial puncture during right internal jugular vein (RIJV) cannulation with and without ultrasound guidance (USG). The secondary end points were to assess if USG improves the chances of successful first pass cannulation and if BMI has an impact on incidence of arterial puncture and the number of attempts that a...

متن کامل

Ultrasonic locating devices for central venous cannulation: meta-analysis.

OBJECTIVES To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. DATA SOURCES 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. DESIGN Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVEN...

متن کامل

An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.

OBJECTIVES To evaluate the frequency of unsuspected posterior vessel wall penetration of the internal jugular vein during ultrasound-guided needle cannulation. DESIGN Prospective, single-blinded observational study. SETTING Urban level I emergency department with an annual census of 80,000. PATIENTS Residents who had previously completed a 2-day ultrasound course including a 3-hr didactic...

متن کامل

A randomized crossover study comparing a novel needle guidance technology for simulated internal jugular vein cannulation.

BACKGROUND Despite ultrasound guidance for central line placement, complications persist, as exact needle location is often difficult to confirm with standard two-dimension ultrasound. A novel real-time needle guidance technology has recently become available (eZono, Germany) that tracks the needle during insertion. This randomized, blinded, crossover study examined whether this needle guidance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2010