Percutaneous intramedullary rod interchange in osteogenesis imperfecta.

نویسندگان

  • R W Middleton
  • R B Frost
چکیده

This paper describes the design, development and early surgical experience with a stereotactic device to allow closed retrieval and interchange of intramedullary rods in children with osteogenesis imperfecta. This relatively atraumatic procedure may allow more frequent rod interchange than with other techniques, lessening the likelihood of deformity and fracture in the unsupported skeleton when the bone has outgrown the intramedullary rod. The procedure was developed by design studies in vitro followed by intramedullary rodding of tibiae of New Zealand white rabbits. It has been used in children 12 times, in six tibiae and six femora: 11 rods have been successfully retrieved, with rod interchange in eight of these cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical stabilisation of the lower limb in osteogenesis imperfecta using the Sheffield Telescopic Intramedullary Rod System.

The Sheffield Expanding Intramedullary Rod System was developed after experiencing problems with existing rod systems in the management of osteogenesis imperfecta. Between 1986 and 1996 we treated 74 bones in the lower limb in 28 children at a median follow-up of 5.25 years. We have reviewed 24 children with a total of 60 rods. Before surgery, all children had had multiple fractures of the lowe...

متن کامل

Effects of a telescopic intramedullary rod for treating patients with osteogenesis imperfecta of the femur

Purpose To introduce a new model of telescopic intramedullary rod (TIR), evaluate its effects on treating patients presenting with moderate and severe osteogenesis imperfecta (OI) and to compare the findings with those of other telescopic rods. Methods A total of 21 patients (nine girls and 12 boys; mean age at first operation, 6.6 years, 1.52 to 13.18) who underwent 52 femoral operations wer...

متن کامل

Fracture in long bones stabilised by telescopic intramedullary rods in patients with osteogenesis imperfecta.

We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation w...

متن کامل

Femoral non-elongating rodding in osteogenesis imperfecta - the importance of purchasing epiphyseal plate.

BACKGROUND Corrective osteotomy and intramedullary rodding are widely used in children with osteogenesis imperfecta (OI), but revision rodding is often required. This study aims to investigate the effect of purchasing distal femoral epiphysis on the longevity of fixation using non-elongating rod. METHODS We investigated children with Sillence type III or IV OI who received antegrade femoral R...

متن کامل

Interlocking telescopic rod for patients with osteogenesis imperfecta.

BACKGROUND Intramedullary fixation with use of a telescopic rod with a T-piece is one of the standard methods for long-bone stabilization in growing children with osteogenesis imperfecta. However, installation and removal of this device can cause substantial damage to the distal joint, which limits its use, especially in the tibia. We devised a modification of the telescopic rod system--the int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 69 3  شماره 

صفحات  -

تاریخ انتشار 1987