Xrf Analysis of Harmful Metals Collected onto Filters as Thin Layers from Workplace Air: Inter-laboratory Exercise

نویسنده

  • Robert D. Foster
چکیده

An inter-laboratory exercise has been carried out to evaluate the analytical performance of Method for Determining Hazardous Substances: MDHS 91 for determining Metals and metalloids in workplace air by X-ray fluorescence spectrometry, published by the Health and Safety Executive, United Kingdom. Sets of prepared filter standards were used to “transport” a master calibration established on an X-ray spectrometer at the Health and Safety Laboratory (HSL) to a wide range of makes and types of X-ray spectrometers in over 20 participant laboratories. By subsequent analysis of test filter samples prepared by collection of particulate fume generated from ferrous and non-ferrous alloys, it has been demonstrated that both wavelength-dispersive and high resolution energy-dispersive instruments produced results for masses of most toxic elements of interest to occupational hygiene which were mostly (p>0.75) within 10% or 2μg, and nearly always (p>0.9) within 20% or 3μg, of masses previously determined at HSL. Exceptions were elements measured using analytical lines yielding low X-ray count rates /μg – arsenic (As Kβ), tin (Sn Kα) and antimony (Sb Kα). However, even for these elements, over half (p>0.55) of the masses reported were within 10% and nearly all (p>0.9) were within 20% of masses previously determined, provided these were in excess of 15 μg. It was not possible on the basis of the exercise to make generalisations about the performance of energy-dispersive instruments using Peltier-cooled detectors, because such instruments were poorly represented and because such detectors vary so widely in their sensitivities and energy resolving powers. Nevertheless, it was shown that MDHS 91, is applicable to a range of X-ray fluorescence spectrometers, including wavelength dispersive instruments, energy-dispersive instruments and those using radiation source excitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AN IMPROVED AEROSOL GENERATION SYSTEM FOR THE PREPARATION OF XRF CALIBRATION FILTERS, C. Vanhoof, V. Corthouts and N. De Brucker, pp. 449-455

A fast and reliable method for the analysis of airborne loaded filters becomes more and more important for monitoring campaigns and inventory studies at sites with airborne pollution. Xray fluorescence spectroscopy (XRF) can perform quantitative analysis on filters without any pretreatment. Quantitative determination of various metals on loaded filters requires the use of calibration curves set...

متن کامل

PARAMETER STUDIES FOR AN OPTIMIZED XRF-DETERMINATION OF Pb IN BONE

One of the main threats to human health from heavy metals is associated with the exposure to lead (Pb). In vivo X-ray fluorescence analysis (XRF) of human bone is a widely used technique to determine the total Pb body burden. The intention of this work was to study the feasibility of in vivo L-shell XRF measurements of Pb in bone using X-ray tubes as excitation sources. Parameter studies using ...

متن کامل

Immediate screening of lead exposure in the workplace using portable X-ray fluorescence

The use of a portable X-ray fluorescence spectrometer (PXRF) equipped with a miniaturised X-ray tube producing a small 8 mm diameter X-ray beam required the validation of two new sampling protocols for the immediate screening of occupational lead exposure. First, lead in dust and fumes, collected by Institute of Occupational Medicine (IOM) inhalable samplers on 25 mm diameter membrane filters, ...

متن کامل

A Comparison of True Alpha Activities in Air Filter Samples with Values Obtained from Radioactivity-in-air Monitors

A fundamental problem with measurements of alpha activity on air filters from the nuclear workplace is that the calibration sources used with radioactivity-in-air monitors are not in the same physical form as actual samples. The samples suffer from alpha absorption due to effects such as self-attenuation within the radioactive particle, entrapment of the particle within the filter, and the accu...

متن کامل

Experimental Parameters for XRF Analysis of Soils

Harmful elements (Pb, Se, Cd, etc.) in the soil samples were measured by X-ray fluorescence (XRF) method. We investigated the influence of the thickness of soil layer, the grain size of soils, and the water content in soils on XRF intensity. Since high-energy XRF such as Cd K was detected in deep inside of soils, a thickness of 10 mm was recommended. The soil sample with a small grain size gave...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005