High-Pass Filter Characteristics of the Baroreflex – A Comparison of Frequency Domain and Pharmacological Methods

نویسندگان

  • Istvan Bonyhay
  • Marcelo Risk
  • Roy Freeman
چکیده

Pharmacological methods to assess baroreflex sensitivity evoke supra-physiological blood pressure changes whereas computational methods use spontaneous fluctuations of blood pressure. The relationships among the different baroreflex assessment methods are still not fully understood. Although strong advocates for each technique exist, the differences between these methods need further clarification. Understanding the differences between pharmacological and spontaneous baroreflex methods could provide important insight into the baroreflex physiology. We compared the modified Oxford baroreflex gain and the transfer function modulus between spontaneous RR interval and blood pressure fluctuations in 18 healthy subjects (age: 39±10 yrs., BMI: 26±4.9). The transfer function was calculated over the low-frequency range of the RR interval and systolic blood pressure oscillations during random-frequency paced breathing. The average modified Oxford baroreflex gain was lower than the average transfer function modulus (15.7±9.2 ms/mmHg vs. 19.4±10.5 ms/mmHg, P<0.05). The difference between the two baroreflex measures within the individual subjects comprised a systematic difference (relative mean difference: 20.7%) and a random variance (typical error: 3.9 ms/mmHg). The transfer function modulus gradually increased with the frequency within the low-frequency range (LF), on average from 10.4±7.3 ms/mmHg to 21.2±9.8 ms/mmHg across subjects. Narrowing the zone of interest within the LF band produced a decrease in both the systematic difference (relative mean difference: 0.5%) and the random variance (typical error: 2.1 ms/mmHg) between the modified Oxford gain and the transfer function modulus. Our data suggest that the frequency dependent increase in low-frequency transfer function modulus between RR interval and blood pressure fluctuations contributes to both the systematic difference (bias) and the random variance (error) between the pharmacological and transfer function baroreflex measures. This finding suggests that both methodological and physiological factors underlie the observed disagreement between the pharmacological and the transfer function method. Thus both baroreflex measures contribute complementary information and can be considered valid methods for baroreflex sensitivity assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Comparison of Gaussian and Elliptic High Pass Filter

In this paper, Gaussian and elliptic high pass filters are analyzed for image sharpening qualitatively and quantatively . The filters are implemented in frequency domain using matlab software. Experiments are performed to compare the performance of both the filters ,processed images are presented. The results demonstrate that elliptic yields better results.

متن کامل

Performance Comparison of Gaussian and Elliptic High Pass Filter

In this paper, Gaussian and elliptic high pass filters are analyzed for image sharpening qualitatively and quantatively . The filters are implemented in frequency domain using matlab software. Experiments are performed to compare the performance of both the filters ,processed images are presented. The results demonstrate that elliptic yields better results.

متن کامل

A Novel Structure for Realization of a Pseudo Two Path Band-Pass Filter

In this paper, a modified auto zeroed integrator is used to design and simulate a low-voltage high-Q switched capacitor pseudo 2-path filter.  The filter is a sixth–order Chebyshev band-pass filter operating at sampling frequency of 1MHz and center frequency of 250 kHz with a quality factor of 50. The proposed filter has both low-voltage and high speed properties of the auto zeroed integrators ...

متن کامل

An Efficient Algorithm to Design Nearly Perfect-Reconstruction Two-Channel Quadrature Mirror Filter Banks

In this paper, a novel technique for the design of two-channel Quadrature Mirror Filter (QMF) banks with linear phase in frequency domain is presented. To satisfy the exact reconstruction condition of the filter bank, low-pass prototype filter response in pass-band, transition band and stop band is optimized using unconstrained indirect update optimization method. The objective function is form...

متن کامل

Dual-Band Evanescent-Mode Substrate Integrated Waveguide Band-pass Filter for WLAN Applications

A new multi-layer substrate integrated waveguide (SIW) structure is developed to design dual-band evanescent-mode band-pass filters (BPFs). Two independent series LC circuits are implemented by incorporating metallic irises in the different layers of the structure. The combination of the metallic irises with capacitive-plates is embedded inside the SIW to independently excite two evane...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013