Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
نویسندگان
چکیده
This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy.Thedeveloped algorithm is validated by simulation tests usingMATLABSimulink.Theobtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.
منابع مشابه
Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملControl strategies for harmonic mitigation and power factor correction using shunt active filter under various source voltage conditions
This paper gives a new insight into the concept of load compensation using shunt active filter (SAF) under ideal and non-ideal source voltage conditions. A novel approach based on an improved instantaneous active and reactive current component method is proposed. The performance of the proposed control strategy has been compared with instantaneous reactive power theory, symmetrical component th...
متن کاملPerformance Investigation of Active Power Line Conditioner using Simulink
Active power conditioners have been developed over the years to solve the problems to improve power quality. Among which shunt active power conditioners is used to eliminate load current harmonics and reactive power compensation. The controller ensures that the dc-side capacitor voltage is nearly constant with small ripple besides extracting fundamental reference currents. The PLL block assists...
متن کاملAnalysis And Simulation Of Shunt Active Power Filter Under Unbalanced And Distorted Load Conditions
Abstract— The active power filters eliminates the harmonic distortion caused by non-linear loads and improves the filtering efficiency performance when compared with the passive filters. This paper inspects about the analysis and simulation of a three phase four wire shunt active power f ilter under unbalanced and distorted load conditions. Current harmonic compensation is achieved by the imple...
متن کاملA Novel Shunt Active Filter Algorithms for a Three Phase System with Unbalanced and Distorted Source Voltage Wave Forms Feeding to Adjustable Speed Drive
This paper presents the simulation of Shunt Active Power filter by using two different control schemes, indirect current control technique and ANN control technique. These two controle techniques are working under both balanced and unbalanced three phase voltage source conditions and it is feeding to a adjustable speed drive the torque speed characteristics of a motor is presented. Indirect cur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- J. Electrical and Computer Engineering
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015