Between-laboratory comparison of densitometry and bio-electrical impedance measurements.
نویسندگان
چکیده
Body composition was measured in nine healthy, normal-weight, weight-stable subjects in three different research centres. In each centre the usual procedures for the measurements were followed. It revealed that the measurement procedures in the three centres were comparable. Body composition was measured in each centre between 09.00 and 13.00 hours after a light breakfast by densitometry (underwater weighing) and bio-electrical impedance. A single, total-body-water determination by D2O dilution was used as a reference value. Body fat determined by densitometry was significantly lower in one centre, which, however, could be completely explained by a lower body weight, probably due to water loss (the subjects refrained for a longer time from food and drinks before the measurements in that centre) and, thus, by violation of the assumptions of Siri's (1961) formula. Also, body impedance was slightly higher in that centre, indicating a lower amount of body water. Mean body fat from densitometry was also slightly lower in that centre compared with body fat determined by D2O dilution. Individual differences between body fat from densitometry and from total body water were relatively large, up to 7% body fat. The relationship between fat-free mass from densitometry and bio-electrical impedance was not different between the centres. It is concluded that differences in the relationship between body composition and bio-electrical impedance, as reported in the literature, may be due to differences in standardization procedures and/or differences in reference population.
منابع مشابه
Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
متن کاملReview Article: Application of Electrical Impedance Spectroscopy in Bladder Cancer Screening
Introduction Bladder cancer is the most common malignancy in elderly people and most bladder cancers are transitional cell carcinomas (TCC). Bladder pathology is usually investigated visually by cystoscopy and this technique can represent different conditions ranging from simple inflammation to flat CIS. However, biopsies must be taken from the suspected area to obtain diagnostic information. T...
متن کاملMicroengineered Conductive Elastomeric Electrodes for Long-Term Electrophysiological Measurements with Consistent Impedance under Stretch
In this research, we develop a micro-engineered conductive elastomeric electrode for measurements of human bio-potentials with the absence of conductive pastes. Mixing the biocompatible polydimethylsiloxane (PDMS) silicone with other biocompatible conductive nano-particles further provides the material with an electrical conductivity. We apply micro-replica mold casting for the micro-structures...
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملEvaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging
Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of nutrition
دوره 71 3 شماره
صفحات -
تاریخ انتشار 1994