Determination of free and total carnitine with a random-access chemistry analyzer.

نویسندگان

  • L Wan
  • R W Hubbard
چکیده

Carnitine deficiency presents as a major problem in fatty acid oxidation. The use of a plasma carnitine assay can rapidly help to describe this deficiency. The method we describe here requires two simple steps of sample preparation, followed by automated analysis with the Beckman Synchron CX4 random-access chemistry analyzer. The goal of this method development was to reduce the cost of analysis and to allow a greater number of laboratories to perform this assay on demand within 1 h for both free and total carnitine. The method has a linearity of 0-150 micromol/L and a detection limit of 5 micromol/L. The inter- and intraday CVs are <20%. The method agreed closely with both the widely used RIA and spectrophotometric methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated analysis for free and short-chain acylcarnitine in plasma with a centrifugal analyzer.

We describe a fully automated, spectrophotometric assay of free and total carnitine in plasma ultrafiltrates. The method, suitable for routine application in most hospital laboratories, incorporates the hydrolysis of acylcarnitines to free carnitine within the program of a Cobas Fara II centrifugal analyzer. The hydrolysis is monitored and calibrated with standard solutions containing octanoylc...

متن کامل

Chemical and clinical evaluation of the random access analyzer "RA-1000".

In the RA-1000, a random-access discrete analyzer, an inert fluorocarbon fluid is used to prevent interaction and carryover. Production-model instruments were evaluated in two laboratories with respect to determination of glucose, creatinine, total protein, inorganic phosphorus, cholesterol, alkaline phosphatase, lactate dehydrogenase, creatine kinase, gamma-glutamyltransferase, and aspartate a...

متن کامل

Sources of error in determinations of carnitine and acylcarnitine in plasma.

Radioactive and nonradioactive L-carnitine and acyl-L-carnitine were used to evaluate the washing procedures used during the determination of free, total, short-chain, and long-chain acylcarnitine in human and sheep plasma. The volume of fluid trapped by the protein precipitated by perchloric acid is approximately 24% of the total fluid volume and thus contains 24% of free carnitine and short-c...

متن کامل

A modified method for the determination of organic mercury in biota [great cormorants (phalacrocorax carbo)] by advanced mercury analyzer

Background: Contagion of aquatic ecosystems to heavy metals especially mercury (Hg) has risen concerns about healthiness of marine organisms. Organic mercury compounds are highly toxic for animals, and its detection in various samples is frequently needed. In present study we have described a new method for measurement of organic mercury and total mercury concentration in great cormorants (ph...

متن کامل

Automated method for L-carnitine determination.

Because of renewed interest in a possible connection between carnitine, lipid disorders, and myopathy, an automated method of analysis is desirable. Deproteinization of serum by use of membrane filter cones and automated assay with a bichromatic analyzer (the ABA-100) substantially increases efficiency without sacrificing the specificity and accuracy of the original manual enzymatic method. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 4  شماره 

صفحات  -