How effective are added constraints in improving TKR kinematics?

نویسندگان

  • B H van Duren
  • H Pandit
  • D J Beard
  • A B Zavatsky
  • J A Gallagher
  • N P Thomas
  • D T Shakespeare
  • D W Murray
  • H S Gill
چکیده

Newer designs of total knee arthroplasty (TKA), through the use of added degrees of constraint, attempt to provide a "guided motion" to restore more normal and predictable kinematics. Two such design philosophies are the posterior stabilised (PS) using a cam-post and the medial pivot (MP) concepts. Knee kinematics of 12 patients with a PS TKA, 13 subjects with a MP TKA and 10 normal subjects were compared. For kinematic assessment, patients underwent fluoroscopic assessment of the knee during a step-up exercise and deep knee bend. Fluoroscopic images were corrected for distortion and assessed using 3D model fitting to determine relative 3D motion, and a 2D method to measure the patellar tendon angle (PTA) as function of knee flexion. For the PS design the cam-post mechanism engaged between 70 degrees and 100 degrees flexion. Between extension and 50 degrees there was forward motion of the contact points. Beyond 60 degrees both condyles rolled moved posteriorly. The majority of the external rotation of the femur occurred between 50 degrees and 80 degrees . The PTA was lower than normal in extension and higher than normal in flexion. The MP exhibited no anterior movement throughout the rage of motion. The medial condyle moved minimally. The lateral contact point moved posteriorly from extension to flexion. The femur rotated externally throughout the range of flexion analysed. The PTA was similar to normal from extension to mid flexion and then higher than normal beyond to high flexion. The PS design fails to fully restrain paradoxical anterior movement and although the cam engages, it does not contribute significantly to overall rollback. The MP knee does not show significant anterior movement, the medial pivot concept appears to achieve near normal kinematics from extension to 50 degrees of knee flexion. However, the results show that at high flexion this design does not achieve normal knee kinematics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Knee Kinematic Improvement After Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method

Objectives: The aim of this study was to extract suitable spatiotemporal and kinematic parameters to determine how Total Knee Replacement (TKR) alters patients’ knee kinematics during gait, using a rapid and simplified quantitative two-dimensional gait analysis procedure. Methods: Two-dimensional kinematic gait pattern of 10 participants were collected before and after the TKR surgery,...

متن کامل

Measurement of Artificial Knee Joint Kinematics using Pattern Matching Method

Introduction An increase in demand of Total Knee Replacement (TKR) has necessarily required us to design a better TKR from durability and endurance aspects. Measurement of prosthetic kinematics will bring us significant information on the TKR design. The image-based technique may be highly feasible for in-vivo measurement as compared to other sophisticated techniques. In this study, the pattern...

متن کامل

Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement.

Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect functional outcome. Two important determinants of knee kinematics are component geometry and the presence or absence of a posterior-stabilising mechanism (cam-post). We investigated the influence of these variables by comparing the kinematics of a TKR with a polyradial femur with a single radius design, both wi...

متن کامل

A method to quantify alteration of knee kinematics caused by changes of TKR positioning.

Few in-vitro studies have investigated changes in kinematics caused by total knee replacement (TKR) implantation. The advent of surgical navigation systems allows implant position to be measured accurately and the effects of alteration of TKR position and alignment investigated. A test rig and protocol were developed to compare the kinematics of TKR-implanted knees for different femoral compone...

متن کامل

Subsumption and Recognition of Heterogeneous Constraint

Terminological knowledge representation (tkr) systems such as kl-one are widely used in AI to construct concept taxonomies based on subsumption inferences. However , current tkr systems are unable to represent temporal patterns or recognize instances of such patterns from ongoing observations. Motivated by applications such as service personnel dispatching and plan recognition for interactive u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 40 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2007