Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study.

نویسندگان

  • P Quesada
  • H B Skinner
چکیده

In this study, a finite element (FE) model of a below-knee prosthesis of patellar tendon-bearing (PTB) design, and several altered variations of the model have been constructed. A load of approximately 1.5 times normal body weight (984 N) was applied at the heel of the model to simulate heelstrike conditions. The "base" model was then analyzed and revised iteratively until a model which provided consistency between soft tissue elastic modulus and socket displacement was developed. The interface normal and shear stresses obtained from the analysis of this revised base model were highest (about 961, and 463 KPa, respectively) at the distal anterior tip of the socket/stump. Proximally, higher normal stresses (72-78 KPa) were found medially and posteriorly. Proximal shear stresses were highest posteriorly (79 KPa), although shear stresses medially (51 KPa), and laterally (43 KPa), were also much higher than anteriorly (10 KPa). FE analyses were performed on the altered models to determine the relative effects on socket/stump interface stresses of altering the FE model of the prosthesis. Results of the analysis indicate that fabricating the prosthesis from a material with an elastic modulus ten times lower than that of the revised base model can produce reductions in the maximum pressure of up to 14 percent. Large decreases in maximum pressures (71 percent) resulted from the use of a suction socket rather than a conventional socket. Small changes in stump length (2 cm) caused relatively large pressure changes (16 to 18 percent).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evolution of functional bracing of fractures.

©2006 British Editorial Society of Bone and Joint Surgery doi:10.1302/0301-620X.88B2. 16381 $2.00 J Bone Joint Surg [Br] 2006;88-B:141-8. Functional fracture bracing, described in 1967, 1 was inspired by the patellar-tendonbearing prosthesis which had recently been developed for below-knee amputees. This prosthesis had eliminated the traditional thigh corset and allowed the transfer of weight-b...

متن کامل

Application of prosthetics-orthotics principles to treatment of fractures.

1 School of Medicine, University of Miami, Jackson Memorial Hospital, Miami, Fla. 33152. Greater knowledge and understanding of bioengineering by the prosthetics and orthotics industries during the past twenty years have resulted in the development of highly functional and sophisticated appliances. For example, modern prostheses for lowerand upperextremity amputees are now designed with proper ...

متن کامل

Pressures in critical regions of the below-knee patellar-tendon-bearing prosthesis.

In a biomechanical analysis of the forces transmitted to an amputated limb by a below-knee patellar-tendon-bearing prosthesis, R@di% (1) showed in 1962 that the principal forces occur in the patellar ten bn, the distal anterior tibial, the latera tibial condylar, and the medial tibial condylar regions. Apparantly the design of this prosthesis was such that the forces were directed to those area...

متن کامل

Recent advances in below-knee prosthetics.

' Executive Director, Committee on Prosthetics Research and Development, National Research Council, 2101 Constitution Ave., N. W., Washington, D.C. 20418. The concept of constructing a belowknee prosthesis with side joints and a thigh lacer was set forth by the Dutch surgeon Verduin in 1696 (Fig. 1) and followed universally until the advent of the patellar-tendon-bearing prosthesis in the late ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 1991