Echocardiographic measurement of cardiac output in rats.
نویسندگان
چکیده
The systematic evaluation of different transthoracic echocardiographic (TTE) methods to determine cardiac output (CO) and the effect of changes in intravascular volume on echocardiographically determined indexes of cardiovascular structure in the rat has not been documented. With the use of 11 Wistar rats, simultaneous echocardiographic and thermodilution measurements of CO were compared at baseline and after blood withdrawal or transfusion at 43 different levels of intravascular volume and using 10 different echocardiographic approaches. The best correlation (r = 0.93; P < 0.0001), least bias (-3 ml/min), and best precision (16 ml/min) between thermodilution and echocardiographic methods were obtained at the level of aortic annulus using pulsed Doppler. In conclusion, CO could be accurately assessed in rats using TTE and pulsed Doppler at the level of the aortic annulus. This annulus was demonstrated to remain stable, but pulmonary annulus, thoracic aorta, mitral valve, and left ventricular diameters were found to be more modifiable during volumic changes.
منابع مشابه
Normal Echocardiographic Findings in Healthy Pigeons
Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...
متن کاملA comparison between the effects of Portulaca oleracea seeds extract and valsartan on echocardiographic and hemodynamic parameters in rats with levothyroxine-induced thyrotoxicosis
Objective: The aim of the present study was to compare the effects of Portulaca oleracea (Po) seeds extract and those of valsartan on cardiac function in levothyroxine (T4)-treated rats. Materials and Methods: Forty Wistar rats were divided into four groups (n=10): control, levothyroxine (T4), T4 plus valsartan (T4-Val) and T4 plus hydro-alcoholic extract of the P. oleracea seeds (T4-Po). Contr...
متن کاملTransoesophageal pulsed wave Doppler measurement of cardiac output during major vascular surgery: comparison with the thermodilution technique.
We measured cardiac output in 12 patients undergoing elective abdominal vascular surgery at specific times during the procedure with simultaneous thermodilution and transoesophageal pulsed Doppler echocardiographic techniques. No patient had clinical evidence of valvular heart disease before surgery. Five patients had echocardiographic evidence of mitral regurgitation on colour-coded Doppler. U...
متن کاملTransoesophageal Doppler echocardiographic measurement of cardiac output by the mitral annulus method.
OBJECTIVE To compare cardiac output measured by the transoesophageal Doppler and thermodilution techniques. DESIGN Prospective direct comparison of paired measurements by both techniques in each patient. SETTING Intensive care unit in a cardiovascular centre. PATIENTS 65 patients after open heart surgery (mean (SD) age 53 (12) years). INTERVENTIONS Cardiac output was measured simultaneo...
متن کاملMeasurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 284 2 شماره
صفحات -
تاریخ انتشار 2003