The influence of sample freezing at – 80 °C for 2–12 weeks on glycated haemoglobin (HbA1c) concentration assayed by HPLC method on Bio-Rad D-10® auto analyzer

نویسندگان

  • Katarzyna Bergmann
  • Grazyna Sypniewska
چکیده

INTRODUCTION The aim of the study was to evaluate the effect of a single freeze/thaw cycle on HbA1c concentrations measured by commercially available HPLC method. MATERIALS AND METHODS Study included 128 whole blood samples collected from diabetic patients (N = 60) and healthy volunteers (N = 68). HbA1c concentrations were measured in fresh blood samples. Then samples were frozen at - 80 °C for up to 12 weeks. HbA1c was assayed by ion-exchange HPLC method on Bio-Rad D-10® analyzer. Variables were compared using Wilcoxon and ANOVA Kruskal-Wallis tests. Bias between HbA1c measured in fresh and frozen samples was calculated. The comparability of HbA1c concentrations was assessed by Bland-Altman plot. RESULTS Median (IQR) HbA1c concentration was 45.3 (36.6-61.2) mmol/mol for fresh and 45.3 (36.6-60.6) mmol/mol for frozen/thawed samples. No significant difference in HbA1c concentrations was found comparing fresh and frozen/thawed samples (P = 0.070) in the whole group, as well as in healthy and diabetic subjects. The median calculated bias between fresh and frozen/thawed samples was 0% in whole group and healthy subjects, and 1.19% in diabetic patients. No significant difference was found between the biases according to baseline HbA1c values (P = 0.150). The Bland-Altman plot analysis showed a positive bias of 0.4% (95% CI: - 2.8 - 3.7%), which indicates high compliance between HbA1c values and no relevant influence of sample freezing on clinical significance of HbA1c measurement. CONCLUSIONS Storage for up to 12 weeks at - 80 °C with a single freeze/thaw cycle does not affect HbA1c concentrations measured with HPLC method on Bio-Rad D-10® analyzer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Labile glycated haemoglobin and carbamylated haemoglobin are still critical points for HbA1c measurement

INTRODUCTION Haemoglobin A1c (HbA1c) is a key analyte for the monitoring of glycemic balance in diabetic patients and is used for diabetes diagnosis in many countries. The potential interference of carbamylated haemoglobin (cHb) and labile glycated haemoglobin (LA1c) on HbA1c assays must remain a matter of vigilance. Such a situation has occurred in our laboratory with a kit replacement on the ...

متن کامل

Effect of HbE trait on measurement of HbA1c by three different methods.

Sir, HbA1c testing is mainly used for monitoring glycaemic control in patients with diabetes. However, the World Health Organization now recommends that HbA1c can be used as a diagnostic test for diabetes, provided that stringent quality assurance procedures are in place and assays are standardised to criteria aligned to the international reference values. Laboratories use many different method...

متن کامل

Correlation between glycated haemoglobin levels and random blood glucose.

BACKGROUND Glycated haemoglobin or glycosylated haemoglobin (HbA1c) is a form of haemoglobin that is measured primarily to identify the average plasma glucose concentration over prolonged periods of time. Levels of HbA1c represent the average blood glucose levels of diabetic patients over the previous 120 days. The objective of this study was to see the correlation between HbA1c levels and rand...

متن کامل

Capillarys 3 Octa®: Analytical Performance Assessment for HbA1c Quantification

Objective: Determination of HbA1c level is a precious indicator for therapeutic follow-up of patients with type 1 or type 2 diabetes. Our study aimed to evaluate the analytical characteristics of Capillarys 3 Octa® HbA1c measurement by capillary electrophoresis. Materials and Methods: Our study involved 265 venous whole blood specimens repeatability, intermediate fidelity, accuracy, linearity,...

متن کامل

Evaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V

OBJECTIVES To evaluate the Bio-Rad D-100®, an HPLC analyzer for glycated hemoglobin (HbA1c) determination, and to compare its performance with the Menarini HA-8180V® and Sysmex G8®. METHODS Method comparison was performed according to Clinical and Laboratory Standards Institute (CLSI) EP9-A2 guidelines. We selected 100 samples from the routine laboratory workload and analyzed them in duplicat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2016