Comment on “Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye”
نویسنده
چکیده
An interesting method to measure and correct chromatic magnification offsets in a multi-wavelength retinal imaging microscope was recently reported [Harmening et al., Biomed. Opt. Express 3, 2066 (2012)]. These values were in part related to the ocular transverse chromatic aberration (TCA). This method could be potentially used in the future to overcome the fundamental limitation to estimate the eye's TCA with ophthalmoscopic (double-pass) configurations.
منابع مشابه
Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye
A special challenge arises when pursuing multi-wavelength imaging of retinal tissue in vivo, because the eye's optics must be used as the main focusing elements, and they introduce significant chromatic dispersion. Here we present an image-based method to measure and correct for the eye's transverse chromatic aberrations rapidly, non-invasively, and with high precision. We validate the techniqu...
متن کاملTransverse Chromatic Aberration and Vision: Quantification and Impact across the Visual Field
The eye is our window to the world. Human vision has therefore been extensively studied over the years. However, in-depth studies are often either limited to our central visual field, or, when extended to the periphery, only correct optical errors related to a narrow spectrum of light. This thesis extends the current knowledge by considering the full visible spectrum over a wide visual field. A...
متن کاملEffects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study
Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...
متن کاملImproving the two-wavelength fundus oximetry method for quantitatively measuring retinal oxygen saturation in eye model phantom using a steady state diffusion algorithm
This article has no abstract.
متن کاملIn vivo imaging of retinal pigment epithelium cells in age related macular degeneration.
Morgan and colleagues demonstrated that the RPE cell mosaic can be resolved in the living human eye non-invasively by imaging the short-wavelength autofluorescence using an adaptive optics (AO) ophthalmoscope. This method, based on the assumption that all subjects have the same longitudinal chromatic aberration (LCA) correction, has proved difficult to use in diseased eyes, and in particular th...
متن کامل