[Polyethylene replacement by cementing a new component over the osseointegrated metal-back].

نویسندگان

  • A Espinosa-Ruiz
  • P Zorrilla-Ribot
  • J A Salido-Valle
چکیده

OBJECTIVE In uncemented revision total hip replacement due to polyethylene wear, the metal cup needs to be maintained when its stability is checked during surgery, only replacing the polyethylene that is cemented if anchoring is not possible. The aim of the present study was to evaluate the medium-term clinical and radiological results of a polyethylene liner cemented into an osseointegrated acetabular shell component. MATERIAL AND METHOD A retrospective analysis was performed on 15 patients in whom the surgical indication was polyethylene wear, with a mean follow-up of 6.1 years (range 3.5-9.7 years). The Harris Hip Score was used to assess the clinical results before surgery and at the end of follow-up. Anteroposterior and axial X-rays of the hip were taken to rule out complications. RESULTS The mean Harris Hip Score improved, increasing from 64.7 points before the surgery to 80.3 at the end of follow-up. The osteolytic lesions disappeared, or at least the size did not increase, in the follow-up X-rays. One patient (6.7%) suffered 2 dislocation episodes that were treated without the need for surgery. Another patient presented with aseptic loosening of the femoral stem that required a replacement. CONCLUSIONS Cementing the polyethylene liner, when anchoring is not possible, in an uncemented osseointegrated metal shell is a technique that offers good results in the medium term, and which may minimise the complications that may occur with the replacement of the shell component, without compromising its stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of primary total hip arthroplasty in university hospitals of the European Union.

Current practice in primary total hip replacement was investigated by postal survey in 125 university hospitals of the European Union (EU). Most hospitals (78.4%) use a hip register and implant cemented as well as uncemented stems (72.0%) and cups (68.8%). In Scandinavian & Anglo-Saxon countries, 42.9% of the departments implant cemented stems in all their patients, and 16.7% implant cemented c...

متن کامل

Anisotropic bone remodeling of a biomimetic metal-on-metal hip resurfacing implant.

Hip resurfacing (HR) is a highly attractive option for young and active patients. Some surgeons have advocated cementing the metaphyseal stem of the femoral component to improve fixation and survivorship of HR. However, extending component fixation to the metaphysis may promote femoral head strain shielding, which in turn may reduce survival of the femoral component. Replacing the metallic meta...

متن کامل

Polyethylene wear in uncemented acetabular components.

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...

متن کامل

A modified cementing technique using BoneSource to augment fixation of the acetabulum in a sheep model

BACKGROUND AND PURPOSE Our aim was to assess in an animal model whether the use of HA paste at the cement-bone interface in the acetabulum improves fixation. We examined, in sheep, the effect of interposing a layer of hydroxyapatite cement around the periphery of a polyethylene socket prior to fixing it using polymethylmethacrylate (PMMA). METHODS We performed a randomized study involving 22 ...

متن کامل

Thermal Analysis of the Tibial Cement Interface with Modern Cementing Technique

BACKGROUND The major cause of cemented Total Knee Arthroplasty (TKA) failure is aseptic loosening of the tibial component necessitating revision surgery. Recently, multiple techniques have been described to maximize cement penetration depth and density in the proximal tibia during TKA to potentially avoid early loosening. While cement polymerisation is an exothermic reaction, minimal investigat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cirugia ortopedica y traumatologia

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2015