Automation of blood component preparation from whole blood collections.

نویسندگان

  • J Cid
  • L Magnano
  • M Lozano
چکیده

BACKGROUND AND OBJECTIVES Automation of blood component preparation (BCP) from whole blood (WB) collections is increasingly being widespread implemented. This review summarizes the quality of blood components obtained with new automated devices. MATERIALS AND METHODS We reviewed available literature on the quality of blood components obtained with new automated devices developed in the 2000s. RESULTS Blood components obtained with the new devices met European standards. Of note, compared with platelet concentrates obtained with manual methods, automation of BCP improved the consistency of the final products. CONCLUSION The complete automation of BCP from WB collections is still in development and it represents a huge change in paradigm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conversion from Platelet-Rich Plasma Platelet Production to Buffy Coat Platelet Component Production: Benefits and Limitations

Blood transfusion centers are under considerable pressure to produce platelet concentrates with high quality and safety due to the short shelf life of 3-5 days as well as possible bacterial and viral contaminations. For a variety of reasons, many Europeans have changed their methods of component production from whole blood using the North American standard platelet-rich plasma method to the buf...

متن کامل

شیوع مصرف انواع مشتقات مختلف خون در نوزادان بستری در بیمارستان شهید بهشتی کاشان در سال‌های 1380-1379

The Prevalence of Different Blood Derivatives Consumption in Neonates Admitted to Kashan Shahid Beheshti Hospital (2000-2001)     Considering the significance of blood component therapy in neonates and the potential risks of transfusion in this patient group and due to having little information about the types of blood component used in neonatal unit, this descriptive study was carried out at B...

متن کامل

Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device

Background. We developed a completely closed system based on gravity separation without centrifugation steps for separation of whole blood. With this new system we compared quality and stability of the processed blood components (PRC and plasma) with respect to classical preparation. Furthermore the cost-effectiveness of this hollow fibre system was evaluated. Study Design and Methods. Whole bl...

متن کامل

Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound

Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...

متن کامل

Haemovigilance

Haemovigilance is defined as a set of surveillance procedures from the collection of blood and its components to the follow–up of recipients, denoted to collect and assess information on unexpected or undesirable effects resulting from the therapeutic use of labile blood products, and to prevent their occurrence or recurrence. In this system the complications of blood transfusion are systematic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vox sanguinis

دوره 107 1  شماره 

صفحات  -

تاریخ انتشار 2014