Light sensors for objective light measurement in ambulatory polysomnography

نویسندگان

  • Rachel Schembri
  • Jo Spong
  • Allison Peters
  • Peter Rochford
  • Philip Wilksch
  • Fergal J O'Donoghue
  • Kenneth M Greenwood
  • Maree Barnes
  • Gerard A Kennedy
  • David J Berlowitz
چکیده

Ambulatory polysomnography (PSG) does not commonly include an objective measure of light to determine the time of lights off (Loff), and thus cannot be used to calculate important indices such as sleep onset latency and sleep efficiency. This study examined the technical specifications and appropriateness of a prototype light sensor (LS) for use in ambulatory Compumedics Somte PSG.Two studies were conducted. The first examined the light measurement characteristics of the LS when used with a portable PSG device, specifically recording trace range, linearity, sensitivity, and stability. This involved the LS being exposed to varying incandescent and fluorescent light levels in a light controlled room. Secondly, the LS was trialled in 24 home and 12 hospital ambulatory PSGs to investigate whether light levels in home and hospital settings were within the recording range of the LS, and to quantify the typical light intensity reduction at the time of Loff. A preliminary exploration of clinical utility was also conducted. Linearity between LS voltage and lux was demonstrated, and the LS trace was stable over 14 hours of recording. The observed maximum voltage output of the LS/PSG device was 250 mV, corresponding to a maximum recording range of 350 lux and 523 lux for incandescent and fluorescent light respectively. At the time of Loff, light levels were within the recording range of the LS, and on average dropped by 72 lux (9-245) in the home and 76 lux (4-348) in the hospital setting. Results suggest that clinical utility was greatest in hospital settings where patients are less mobile. The LS was a simple and effective objective marker of light level in portable PSG, which can be used to identify Loff in ambulatory PSG. This allows measurement of additional sleep indices and support with clinical decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differentiating between light and deep sleep stages using an ambulatory device based on peripheral arterial tonometry.

The objective of this study is to develop and assess an automatic algorithm based on the peripheral arterial tone (PAT) signal to differentiate between light and deep sleep stages. The PAT signal is a measure of the pulsatile arterial volume changes at the finger tip reflecting sympathetic tone variations and is recorded by an ambulatory unattended device, the Watch-PAT100, which has been shown...

متن کامل

Gastrointestinal motility during sleep assessed by tracking of telemetric capsules combined with polysomnography - a pilot study.

Studies of gastrointestinal function during sleep are hampered by lack of applicable techniques. Recent development of a novel ambulatory telemetric capsule system, which can be used in conjunction with polysomnography, offers a solution to this problem. The 3D-Transit system consists of ingestible electromagnetic capsules traceable through a portable extracorporeal receiver while traversing th...

متن کامل

Linking Light Exposure and Subsequent Sleep: A Field Polysomnography Study in Humans

Study objectives To determine the effect of light exposure on subsequent sleep characteristics under ambulatory field conditions. Methods Twenty healthy participants were fitted with ambulatory polysomnography (PSG) and wrist-actigraphs to assess light exposure, rest-activity, sleep quality, timing, and architecture. Laboratory salivary dim-light melatonin onset was analyzed to determine endo...

متن کامل

Light Conduction Capability of Different Light-Transmitting FRC Posts

Introduction: Application of light transmitting posts to restore greatly damaged endodontically treated teeth has been increased. It is suspected that light intensity decreases as it passes throughout different materials. This can reduce the degree of conversion required for adequate bond strength throughout the length of these posts. The objective of this study was to evaluate the amount of li...

متن کامل

New Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators

Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017