Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement.
نویسندگان
چکیده
BACKGROUND The prosthesis used for aortic valve replacement (AVR) can be too small in relation to body size, thus causing valve prosthesis-patient mismatch (PPM) and abnormally high transvalvular pressure gradients. This study examined if there is a relation between PPM and short-term mortality after operation. METHODS AND RESULTS The indexed valve effective orifice area (EOA) was estimated for each type and size of prosthesis being implanted in 1266 consecutive patients and used to define PPM as not clinically significant if >0.85 cm2/m2, as moderate if >0.65 cm2/m2 and 120 minutes (P=0.001), and PPM (P=0.003). Relative risk of mortality was increased 2.1-fold (95% confidence interval, 1.2 to 3.7) in patients with moderate PPM and 11.4-fold (4.4 to 29.5) in those with severe PPM. Moreover, risk of mortality for every category of PPM was higher in patients with a left ventricular ejection fraction <40% as compared with >or=40% (nonsignificant PPM, 2.7 versus 1.0; moderate PPM, 7.1 versus 1.8; severe PPM, 77.1 versus 11.3). CONCLUSIONS PPM is a strong and independent predictor of short-term mortality among patients undergoing AVR, and its impact is related both to its degree of severity and the status of left ventricular function. In contrast to other risk factors, moderate-severe PPM can be largely avoided with the use of a prospective strategy at the time of operation.
منابع مشابه
[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].
INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...
متن کاملProsthesis-Patient Mismatch
I n this issue of iJACC, Dayan et al. (1) published a meta-analysis of prosthesis-patient mismatch (PPM) after aortic valve replacement from 58 studies involving 40,381 patients, mostly after surgical aortic valve replacement (SAVR). Their major findings were as follows: 1) moderate or greater (indexed effective orifice area [iEOA] <0.85 cm/m) PPM was associated with increased perioperative mor...
متن کاملMid-term impact of patient-prosthesis mismatch on young and middle-aged patients undergoing surgery due to severe aortic stenosis
Methods All patients younger than 70 years of age undergoing isolated aortic valve replacement from October 2005 to October 2011 were analyzed. Patient-prosthesis mismatch was defined as the indexed effective orifice area ≤ 0,85cm2/m2. We studied the impact of patient-prosthesis mismatch on mid-term overall mortality, cardiac events and New York Heart Association functional class using an analy...
متن کاملAN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT
Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملImpact of patient-prosthesis mismatch following aortic valve replacement on short-term survival: a retrospective single center analysis of 632 consecutive patients with isolated stented biological aortic valve replacement.
OBJECTIVES The impact of patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) on short-term and long-term mortality remains controversial. The objective of this study was to evaluate the incidence and severity of PPM and its impact on short-term survival in a large cohort of patients treated with isolated stented biological AVR in a single institution. METHODS We analyzed re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 108 8 شماره
صفحات -
تاریخ انتشار 2003