A New Approach for Heterogeneity Corrections for Cs-137 Brachytherapy Sources

نویسندگان

  • S. Sina
  • R. Faghihi
  • A. S. Meigooni
چکیده

BACKGROUND Most of the current brachytherapy treatment planning systems (TPS) use the TG-43U1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects. OBJECTIVE The purpose of this study is developing a method for obtaining correction factors for heterogeneity for Cs-137 brachytherapy sources based on pre-calculated MC simulations and interpolation. METHOD To simulate the effect of phantom heterogeneity on dose distribution around Cs-137 sources, spherical water phantoms were simulated in which there were spherical shells of bone with different thicknesses (0.2cm to 1.8cm with 0.1cm increment) at different distances (from 0.1cm to 10cm, with 0.5cm increment) from the source center. The spherical shells with 0.1cm thickness at different distances from 0.1cm to 10cm were used as tally cells. The doses at these cells were obtained by tally types F6, *F8, and *F4.The results indicate that the percentage differences between the doses in heterogeneity sections with the dose at the same positions inside the homogeneous water phantom vary when the distance of bone section from the source center increases, because of decreasing the average energy of photons reaching the bone layer. Finally, the results of Monte Carlo simulations were used as the input data of MATLAB software, and the percentage dose difference for each new configuration (i.e. different thickness of inhomogenity at different distances from the source) was estimated using the 2D interpolation of MATLAB. RESULTS According to the results, the algorithm used in this study, is capable of dose estimation with high accuracy. CONCLUSION The developed method using the results of Monte Carlo simulations and the dose interpolation can be used in treatment planning systems for heterogeneity corrections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach for Heterogeneity Corrections for Cs-137 Brachytherapy Sources

Background: Most of the current brachytherapy treatment planning systems (TPS) use the TG-43U1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects.Objective: The purpose of this study is developing a method for obtaining correction factors for heterogeneity for Cs-137 brachytherapy sources based on pre-calculated MC simulations and interpolation.Method: To ...

متن کامل

Investigation of the Effects of Tissue Inhomogeneities on the Dosimetric Parameters of a Cs-137 Brachytherapy Source using the MCNP4C Code

Introduction: Brachytherapy is the use of small encapsulated radioactive sources in close vicinity of tumors. Various methods are used to obtain the dose distribution around brachytherapy sources. TG-43 is a dosimetry protocol proposed by the AAPM for determining dose distributions around brachytherapy sources. The goal of this study is to update this protocol for presence of bone and air inhom...

متن کامل

Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

متن کامل

Calculating of Dose Distribution in Tongue Brachytherapy by Different Radioisotopes using Monte Carlo Simulation and Comparing by Experimental Data

Introduction: Among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. Brachytherapy is the most common method to cure tongue cancers. Long sources are used in different techniques of tongue brachytherapy. The objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sourc...

متن کامل

A Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015