Pupil Diameter Changes in High Myopes after Collamer Lens Implantation

نویسندگان

  • Dan Li
  • Yabo Yang
  • Caipei Su
  • Houfa Yin
  • Xue Liu
چکیده

PURPOSE To observe the changes in pupil size under photopic and scotopic conditions after Implantable Collamer Lens (ICL) implantations in eyes with high myopia. METHODS The ICL was implanted in 90 eyes belonging to 45 patients with high myopia. Photopic pupil diameters, scotopic pupil diameters, anterior chamber depths, and ICL vaults were examined at the preoperative, postoperative 1-month, and postoperative 3-month stages. The preoperative and postoperative photopic pupil diameters and scotopic pupil diameters were also compared with each other to note the differences between them. The correlations between preoperative and postoperative pupil diameter changes under different light conditions and presurgical refractive error were analyzed alongside patient's age and ICL vault. RESULTS Pupil diameters at both postoperative 1-month and postoperative 3-month stages were smaller than those before operation in distinct light environments, as well as pupil constriction amplitude. Correlation analysis showed that there was a statistically significant correlation between pupil diameter changes under different light conditions and presurgical refractive error at 1 month and 3 months after ICL implantation; pupil diameter decreased more when presurgical refractive error powers were less myopic. Statistically significant correlations were not found, however, with patient's age and ICL vault. Postoperative 1-month and mean postoperative 3-month anterior chamber depths were decreased when compared with preoperative anterior chamber depths. Statistically significant correlations were found in change in preoperative and postoperative anterior chamber depth and ICL vault. No statistically significant difference was found between ICL vault at the postoperative 1-month and postoperative 3-month stages. CONCLUSIONS Pupil diameter may decrease at the 1- and 3-month stages after ICL implantation under both photopic and scotopic conditions. This indicates that reduction of pupil diameter may be caused by mechanical contact between the ICL and the posterior iris surface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study

INTRODUCTION The objective of this study was to evaluate the changes of the anterior chamber (AC) of the eye after implantable Collamer lens (ICL) implantation in high myopia by using the Pentacam. METHODS The prospective study included 34 high myopic patients (34 eyes). All patients were treated with Visian implantable Collamer lens (ICL) (Staar Surgical Co.) implantation. The Pentacam (Ocul...

متن کامل

Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)

BACKGROUND To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. METHODS This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c i...

متن کامل

Posterior Vitreous Detachment and Retinal Detachment After Implantation of the Visian Phakic Implantable Collamer Lens

INTRODUCTION To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. MATERIALS AND METHODS This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May ...

متن کامل

The Effects of Age, Refractive Status, and Luminance on Pupil Size

PURPOSE Pupil size is critical for optimal performance of presbyopic contact lenses. Although the effect of luminance is well known, little information is available regarding other contributing factors such as aging and refractive status. METHODS The cohort population comprised 304 patients (127 male, 177 female) aged 18 to 78 years. Pupils were photographed at three controlled luminance leve...

متن کامل

Colvard pupillometer measurement of scotopic pupil diameter in emmetropes and myopes.

PURPOSE To prospectively compare the scotopic pupil size between emmetropes and myopes using a Colvard pupillometer. METHODS The pupil diameters of 55 normal subjects and 55 healthy myopic subjects were measured with the Colvard pupillometer in a low-light situation that simulated the level of light encountered while driving at night. RESULTS The mean (+/- SD) age of the emmetropic subjects...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 92  شماره 

صفحات  -

تاریخ انتشار 2015