THz pulse doubler at FLASH: double pulses for pump–probe experiments at X-ray FELs
نویسندگان
چکیده
FLASH, the X-ray free-electron laser in Hamburg, Germany, employs a narrowband high-field accelerator THz source for unique THz pump X-ray probe experiments. However, the large difference in optical paths of the THz and X-ray beamlines prevents utilization of the machine's full potential (e.g. extreme pulse energies in the soft X-ray range). To solve this issue, lasing of double electron bunches, separated by 28 periods of the driving radiofrequency (at 1.3 GHz), timed for the temporal overlap of THz and X-ray pulses at the experimental station has been employed. In order to optimize conditions for a typical THz pump X-ray probe experiment, X-ray lasing of the first bunch to one-sixth of that of the second has been suppressed. Finally, synchronization of THz radiation pulses was measured to be ∼20 fs (r.m.s.), and a solution for monitoring the arrival time for achieving higher temporal resolution is presented.
منابع مشابه
Simulation of FEL pulse length calculation with THz streaking method
Having accurate and comprehensive photon diagnostics for the X-ray pulses delivered by free-electron laser (FEL) facilities is of utmost importance. Along with various parameters of the photon beam (such as photon energy, beam intensity, etc.), the pulse length measurements are particularly useful both for the machine operators to measure the beam parameters and monitor the stability of the mac...
متن کاملUltrafast Coherent Control and Characterization of Surface Reactions Using Fels
The microscopic understanding of reactions at surfaces requires an in-depth knowledge of the dynamics of elementary processes on an ultrafast timescale. This can be accomplished using an ultrafast excitation to initiate a chemical reaction and then probe the progression of the reaction with an ultrashort x-ray pulse from the FEL. There is a great potential to use atom-specific spectroscopy invo...
متن کاملTHz PUMP AND X-RAY PROBE DEVELOPMENT AT LCLS*
We report on measurements of broadband, intense, coherent transition radiation at terahertz frequencies, generated as the highly compressed electron bunches in LCLS pass through a thin metal foil. The foil is inserted at 45° to the electron beam, 31 m downstream of the undulator. The THz emission passes downward through a diamond window to an optical table below the beamline. A fully compressed...
متن کاملFollowing the dynamics of matter with femtosecond precision using the X-ray streaking method
X-ray Free Electron Lasers (FELs) can produce extremely intense and very short pulses, down to below 10 femtoseconds (fs). Among the key applications are ultrafast time-resolved studies of dynamics of matter by observing responses to fast excitation pulses in a pump-probe manner. Detectors with sufficient time resolution for observing these processes are not available. Therefore, such experimen...
متن کاملTwo-color FEL amplifier for femtosecond-resolution pump-probe experiments with GW-scale X-ray and optical pulses
Pump-probe experiments combining pulses from a X-ray FEL and an optical femtosecond laser are very attractive for sub-picosecond time-resolved studies. Since the synchronization between the two independent light sources to an accuracy of 100 fs is not yet solved, it is proposed to derive both femtosecond radiation pulses from the same electron bunch but from two insertion devices. This eliminat...
متن کامل