Standardization of carotid ultrasound: a hemodynamic method to normalize for interindividual and interequipment variability.

نویسندگان

  • C Ranke
  • A Creutzig
  • H Becker
  • H J Trappe
چکیده

BACKGROUND AND PURPOSE Accurate carotid Doppler examination is an important issue in the light of large endarterectomy trials, but recommended cutoff values for detection of >70% stenosis vary widely. Standardization of diagnostic criteria should consider patient variation and instrument variability. METHODS We prospectively analyzed various Doppler parameters in 44 patients undergoing carotid angiography to evaluate whether normalization through individual reference measurements from the common carotid artery or the distal internal carotid artery could improve accuracy. For assessment of interindividual and interequipment variability, we performed repeated measurements of 40 carotid arteries in 21 patients. Two color-coded duplex ultrasound systems were compared for machine variability estimation: Hewlett Packard SONOS 2500 and ATL Ultramark 9 HDI. RESULTS Intrastenotic divided by distally recorded mean blood flow velocity (mean velocity ratio) showed the closest correlation with angiography: R2=0.93. Mean velocity ratio >5 was 97% sensitive and 98% specific for detection of >70% carotid stenosis. Intrastenotic blood flow velocities were significantly different between the 2 duplex systems (0.22+/-0.16 versus 0.17+/-0. 11 m/s; P<0.001), whereas mean velocity ratio values did not differ significantly. Interobserver variation expressed as 95% CI for predicted stenosis between 2 observers was 13.6% (peak systolic velocity) and 15.4% (mean velocity ratio). CONCLUSIONS A mean velocity ratio using distal reference measurement in the internal carotid artery can normalize for interindividual and interequipment variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Carotid doppler ultrasound evaluation in patients with lichen planus

Background: Lichen planus is a chronic inflammatory disease associated with an increased risk of subclinical atherosclerosis and cardiovascular diseases. This study aimed to evaluate patients with lichen planus using carotid Doppler ultrasound parameters.Methods: Forty patients with lichen planus and 40 controls were included in this study. Common carotid...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Evaluation of the relationship between hepatic and cardiac iron overload with MRI T2* and carotid intima media thickness with Doppler ultrasound in beta thalassemia major patients

Background: Iron overload is caused early progression of atherosclerosis in beta thalassemia patients due to regular repeated blood transfusion. MRI T2* is a gold standard non-invasive method for detecting hepatic and cardiac iron overload. The aim of this study was the comparison of carotid intima media thickness (CIMT) in the patients and healthy control groups with Doppler ultrasound for ear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 1999