Isolated reduction of haematocrit does not compromise in vitro blood coagulation.

نویسندگان

  • B M Iselin
  • P F Willimann
  • B Seifert
  • M Casutt
  • T Bombeli
  • M P Zalunardo
  • T Pasch
  • D R Spahn
چکیده

Low haematocrit values are generally well tolerated in terms of oxygen transport but a low haematocrit might interfere with blood coagulation. We thus sampled 60 ml of blood in 30 healthy volunteers. The blood was centrifuged for 30 min at 2000 g and separated into plasma, which contained the platelet fraction, and packed red blood cells. The blood was subsequently reconstituted by combining the entire plasma fraction with a mixture of packed red blood cells, 0.9% saline, so that the final haematocrit was either 40, 30, 20, or 10%. Blood coagulation was assessed by computerized Thrombelastograph analysis. Data were compared using repeated measures analysis of variance and post-hoc paired t-tests with Bonferroni correction. Decreasing the haematocrit from 40 to 10% resulted in a shortening of reaction time (r) and coagulation time (k), and an increase in angle alpha, maximum amplitude (MA) and clot strength (G) (all P<0.02). This pattern represents acceleration of blood coagulation with low haematocrit values. The isolated reduction in haematocrit, therefore, does not compromise in vitro blood coagulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo effect of haemodilution with saline on coagulation.

EditorÐAs the in¯uence of i.v. ¯uids on the coagulation system is of importance and also sustains the discussion on optimal ¯uid therapy, we would like to comment on the results reported by Ng and colleagues 1 and the suggestions presented in the accompanying editorial. 2 The study design chosen by Ng and colleagues 1 to investigate coagulation and haemodilution might eliminate the in¯uence of ...

متن کامل

In Vitro and in Vivo studies of the Effects of Cold Argon Plasma on Decreasing the Coagulation Time

Introduction Cold plasma is a self-sterilized, painless, and non-contact method in surgeries. These properties allow it to be applied to the living tissues and heat-sensitive parts. The aim of this study was to design a new cold plasma producer device and evaluate the effects of cold argon plasma on decreasing the coagulation time of blood drop in vitro and that of the injured liver blood in vi...

متن کامل

Effects of Methylglyoxal and Aspirin on In Vitro Coagulation and Clot Permeability

Backgrounds and Aims: Methylglyoxal (MGO) is an &ndash;&alpha;, &beta; dicarbonyl aldehyde inevitably produced from triose-phosphate intermediates of glycolysis, and amino acid. Increased MGO in blood leads to alterations in coagulation, clot permeability and thus, atherosclerosis in children with diabetes; however, the precise mechanism is not clear. The present study aimed to compare differen...

متن کامل

Nonsense-mediated mRNA decay among coagulation factor genes

Objective(s): Haemostasis prevents blood loss following vascular injury. It depends on the unique concert of events involving platelets and specific blood proteins, known as coagulation factors. The clotting system requires precise regulation and coordinated reactions to maintain the integrity of the vasculature. Clotting insufficiency mostly occurs due to genetically inherited coagulation fact...

متن کامل

Fluid loss does not explain coagulation activation during air travel.

The mechanism of air travel-related venous thrombosis is unclear. Although immobility plays a pivotal role, other factors such as fluid loss may contribute. We investigated whether fluid loss occurred more in individuals with coagulation activation after air travel than in subjects without. As a secondary aim, we investigated whether fluid loss per se occurred during air travel. In this crossov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2001