Improved wire stiffness with modified connection bolts in Ilizarov external frames: a biomechanical study.
نویسندگان
چکیده
Frame stability in Ilizarov external fixators is mainly dependent on the tension of the transosseous wires, which are clamped to the ring by connection bolts. It was the purpose of this biomechanical study to investigate the holding capacity of a modified bolt design featuring a ruffled wire-bolt interface (TrueLok™) and its influence on wire stiffness in comparison with that of classic bolts featuring a smooth, unruffled wire-bolt interface. Six different ring and bolt configurations were tested using a simplified model consisting of a single ring and wire. The holding capacity at two different tightening torques (10 and 14 Nm) of classic cannulated bolts (CB) and slotted bolts (SB) was determined on Ilizarov and Taylor Spatial Frame (TSF™) rings, whereas the modified TrueLok™ CBs and SBs were used with the TrueLok™ rings. The wire stiffness was calculated via a regression analysis of the load-displacement graphs. The modified TrueLok™ bolts demonstrated significantly better slippage resistance than the classic bolts in all configurations and wire stiffness was significantly higher in the TrueLok™ frame set-ups. After maximum loading, all of the wires showed plastic deformation, including constant wire deflection and dent marks at the clamped wire ends. In conclusion, the decrease in wire stiffness can be explained mainly as a result of wire slippage, but plastic deformation and material yielding also contribute. The relatively simple modification made by roughening the wire-bolt interface results in improved holding capacity and wire stiffness. A frame that contains these modified TrueLok™ bolts should provide improved mechanical stiffness.
منابع مشابه
A new external ring fixator for limb reconstruction: a mechanical study
Background and purpose: The mechanical behavior of an external ring fixator has a direct influence on the bone healing process. In fact, the axial stiffness of the frame and the stability of its elements under repeated loading are essential to promote the bone healing process. In this study we aimed to compare the mechanical behavior of the Stryker Hoffmann LRF (Limb Reconstruction Frame) to tw...
متن کاملA biomechanical analysis of the Ilizarov external fixator.
Five configurations of the Ilizarov fixator were analyzed in vitro. The overall stiffness, shear stiffness, and axial motion of the fracture site were determined. The data were compared with the results of eight conventional one-half frame fixators previously tested in the same manner. The Ilizarov fixator allowed significantly more axial motion at the fracture site during axial compression tha...
متن کاملA Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator
ABSTRACT Taylor's spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4...
متن کاملFatigue behavior of Ilizarov frame versus tibial interlocking nail in a comminuted tibial fracture model: a biomechanical study
BACKGROUND Treatment options for comminuted tibial shaft fractures include plating, intramedullary nailing, and external fixation. No biomechanical comparison between an interlocking tibia nail with external fixation by an Ilizarov frame has been reported to date. In the present study, we compared the fatigue behaviour of Ilizarov frames to interlocking intramedullary nails in a comminuted tibi...
متن کاملThe influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins
BACKGROUND A weight-bearing platform applied at the distal end of an Ilizarov external frame allows patients with hindfoot transfixations, foot deformities or plantar skin lesions to bear weight. This leads to an indirect loading of the fracture or osteotomy site. However, the effect on the fracture/osteotomy site's motion or compressive loads is unknown. The aim of this study was to analyze th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta of bioengineering and biomechanics
دوره 14 4 شماره
صفحات -
تاریخ انتشار 2012