Epidural loss-of-resistance biomechanics: an open pilot cadaver study

نویسندگان

  • William P McKay
  • Timothy Rosser
  • Stefan Kriegler
  • Adel Mohamed
چکیده

PURPOSE We measured dynamic biomechanics of loss-of-resistance (LOR) epidural placement in prone cadavers, focussing on the period immediately following LOR, to estimate forces acting on the tissue of the epidural space. METHODS An epidural syringe with 17G Hustead needle was instrumented to track force on the plunger, pressure in the chamber, and movement of barrel and plunger. Insertions were attempted in five formalin-preserved cadavers from T2-3 to L4-5, using LOR with saline or air, and confirmed with X-ray. RESULTS Sixteen insertions were successful. Soft tissues in formalin-preserved cadavers are much harder than in living humans. With continuous pressure on the plunger, fluid thrust through the needle at the point of LOR was significantly greater (P = 0.005) with saline (mean ± standard deviation [95% confidence intervals]: 19.3 ± 14.9 [8.3 to 30.3] N); than with air (0.17 ± 0.25 [0 to 0.39] N). Stress exerted on epidural tissue was similar (air = 7792 ± 920 [6986 to 8598] Pa; saline = 7378 ± 3019 [5141 to 9614] Pa); and in both cases was greater than the stress exerted by cerebrospinal fluid pushing outwardly on the dura (4800 Pa). CONCLUSION Formalin-preserved cadavers are too stiff to make them an experimental model from which we can generalize to live humans, although we were successful in entering the epidural space and testing the instrumentation for further studies on live animals or humans. Continuous pressure on the plunger while advancing the epidural needle may "blow" the dura away from the needle tip and help prevent dural puncture. Better results are seen with saline rather than air.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards a realistic in vitro experience of epidural Tuohy needle insertion.

The amount of pressure exerted on the syringe and the depth of needle insertion are the two key factors for successfully carrying out epidural procedure. The force feedback from the syringe plunger is helpful in judging the loss of pressure, and the depth of the needle insertion is crucial in identifying when the needle is precisely placed in the epidural space. This article presents the develo...

متن کامل

Effects of different temperatures, velocities and loads on the gliding resistance of flexor digitorum profundus tendons in a human cadaver model.

The purpose of this study was to investigate the effects of temperature, velocity and load on the gliding resistance (GR) of flexor digitorum profundus (FDP) tendons in a human cadaver model. A total of 40 FDP tendons from the index through small digits of ten human cadavers were tested to assess the effect of temperature (4, 23 or 36 °C), velocity (2, 4, 6, 8, 10 or 12 mm/s) and load (250, 500...

متن کامل

Loss of resistance to saline reduces responses accompanying spinal needle insertion during institution of 'needle-through-needle' combined spinal-epidural analgesia.

Normal saline or air is used to identify loss of resistance during identification of the epidural space for combined spinal-epidural analgesia. Following epidural needle placement using air for loss of resistance, up to 80% of parturients move, grimace, vocalise or experience paraesthesia or dysaesthesia during subsequent dural puncture by a spinal needle. We compared the effects of saline vers...

متن کامل

Use of Imaging Agent to Determine Postoperative Indwelling Epidural Catheter Position

BACKGROUND Epidural anesthesia is widely used to provide pain relief, whether for surgical anesthesia, postoperative analgesia, treatment of chronic pain, or to facilitate painless childbirth. In many cases, however, the epidural catheter is inserted blindly and the indwelling catheter position is almost always uncertain. METHODS In this study, the loss-of-resistance technique was used and an...

متن کامل

Ligamentous Restraints of the Second Tarsometatarsal Joint: omeiehanical Evaluation

Ligamentous injury of the tarsometatarsal joint complex 1s an uncommon, but disabling condition that frequently oeeurs In elite athlegs. There are few options for managing these injuries, in part because the relative mechanical contribution of the ligaments af the tarsomcJtatars'sal joint is unknown, complicating decisions regarding which ligaments need reconstruction. In the current study, str...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010