Thermal Analysis of the Tibial Cement Interface with Modern Cementing Technique
نویسندگان
چکیده
BACKGROUND The major cause of cemented Total Knee Arthroplasty (TKA) failure is aseptic loosening of the tibial component necessitating revision surgery. Recently, multiple techniques have been described to maximize cement penetration depth and density in the proximal tibia during TKA to potentially avoid early loosening. While cement polymerisation is an exothermic reaction, minimal investigation into the proximal tibial thermal safety margin during cement polymerisation has been undertaken. In animal models osseous injury occurs at temperatures greater than 47 °C when applied for one minute. The aim of this study was to investigate the cement bone interface temperatures in TKA using modern tibial cementing techniques with a cadaveric tibial tray model. METHODS Eight adult cadavers were obtained with the proximal tibial surface prepared by a fellowship trained arthroplasty surgeon. Third generation cementation techniques were used and temperatures during cement polymerization on cadaveric knee arthroplasty models were recorded using thermocouples. RESULTS The results showed that no tibial cement temperature exceeded 44 °C for more than 1 minute. Two of the eight cadaveric tibias recorded maximum temperatures greater than 44 °C for 55 seconds and 33 seconds, just less than the 60 seconds reported to cause thermal injury. Average maximum polymerization temperatures did not correlate with deeper cement penetration or tray material. Maximum mantle temperatures were not statistically different between metal and all polyethylene tibial trays. CONCLUSION Our investigation suggests that modern cementing techniques result in maximum mantle temperatures that are less than previously recorded temperatures required to cause thermal osseous injury, although this thermal injury safety margin is quite narrow at an average of 4.95 °C (95% confidence interval ± 4.31).
منابع مشابه
Surface pretreatment for prolonged survival of cemented tibial prosthesis components: full- vs. surface-cementation technique
BACKGROUND One of few persisting problems of cemented total knee arthroplasty (TKA) is aseptic loosening of tibial component due to degradation of the interface between bone cement and metallic tibial shaft component, particularly for surface cemented tibial components. Surface cementation technique has important clinical meaning in case of revision and for avoidance of stress shielding. Degrad...
متن کاملFull versus surface tibial baseplate cementation in total knee arthroplasty.
The use of a keel in the tibial component during modern primary total knee arthroplasty (TKA) has become common, and its cementation may affect the future performance of the prosthesis. Although proponents of cementing the entire tibial component argue that this technique provides better initial fixation and may prevent aseptic loosening, reasons exist to apply cement only to the tibial basepla...
متن کاملRevision of tibial TKA components: bone loss is independent of cementing type and technique: an in vitro cadaver study
BACKGROUND Different bone cements and various cementation techniques can lead to different bone loss in revision surgery. We investigated the degree of tibial bone loss depending on different cements and techniques. METHODS 30 tibia specimens were matched into three groups (10 each). In all cases Genesis II tibia component were implanted. In two groups, the tibia base plate alone was cemented...
متن کاملCement penetration and stiffness of the cement-bone composite in the proximal tibia in a porcine model.
PURPOSE To assess the stiffness of the cement bone composite and the depth and uniformity of cement penetration into the surface of the tibial component during total knee reconstruction in a porcine model. METHODS The effectiveness of 3 protocols were compared: 2 commonly used cementing techniques-finger-packing of cement on the cut surface followed by impaction, and coating of the undersurfa...
متن کاملCemented tibial stems are not requisite in revision.
Tibial stems are necessary in most total knee revisions to share the load and protect the fixation interface of the tibial tray. Successful use of a tibial stem requires independent stability of the stem with or without cement. Some additional geometry on the undersurface of the tibial tray such as peripheral pegs or fins is necessary to provide additional resistance to rotatory stresses if the...
متن کامل