Prevention of bacterial leakage at implant-abutment connection level: an in vitro study of the efficacy of three different implant systems.

نویسندگان

  • F Carinci
  • D Lauritano
  • F Cura
  • M A Lopez
  • M Andreasi Bassi
  • L Confalone
  • F Pezzetti
چکیده

Peri-implantitis is the main cause of implant failures. Peri-implantitis is provoked by the presence of bacterial infiltration around Implant-Abutment Connection (IAC). Reduction of bacterial leakage may be achieved by improving the accuracy and precision of the two pieces of IAC. The aim of the present in vitro study was to evaluate bacterial microleakage from the inside to the outside of the IAC, testing the efficacy of three new designs of internal conical connection (FN - nano-fix -, NQ - uNiQo - and Elisir implant systems by FMD, Rome, Italy). To identify the efficacy of three new IAC, the passage of genetically modified Escherichia coli across IAC was evaluated. A total of 17 implants were used (5 FN, 6 NQ and 6 Elisir). All implants were immerged in a bacterial culture for 48 h and bacteria amount was then measured inside and outside IAC with Real-time PCR. Bacterial quantification was performed by Real-Time Polymerase Chain Reaction using the absolute quantification with the standard curve method. In all the tested implants, bacteria were found in the inner side, with a median percentage of 1.9% FN, 1.4% NQ and 2.6% Elisir. The analysis revealed that in both cases (internally and externally), bacteria grew in the first 48 hours but subsequently started to die, probably due to nutrient consumption. Of the three, the most efficacious connection was NQ. Within the limitations of this study, it was concluded that the best implant connection reducing bacterial leakage al IAC level was NQ (NQ implant system by FMD, Rome, Italy).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Comparative study of two different implants with hexogonal connection on the amount of bacteria accumulated at the implant platform site: An in-vivo study

Background and Aims: Nowadays, the best choice for replacing missing teeth are dental implants, however, failure is not unexpected. One of the factors that plays an important role in the implant failure is bacterial microleakage which could cause biological complication. The aim of this study was to compare the bacterial microleakage between the two types of implants. Materials and Methods:...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Microbiological Sealing Analysis of a Tapered Connection and External Hexagon System

Considering the variety of implant connection systems available in the market and the contrasting literature regarding tapered connection systems in terms of bacterial leakage, the aim of this in vitro study was to compare the effectiveness of the bacterial seal at the implant/abutment interface between an external hexagon and a tapered connection system. Twelve sets of indexed tapered connecti...

متن کامل

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biological regulators and homeostatic agents

دوره 30 2 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2016