Thalamic lesions in vascular dementia: low sensitivity of fluid-attenuated inversion recovery (FLAIR) imaging.

نویسندگان

  • António J Bastos Leite
  • Elisabeth C W van Straaten
  • Philip Scheltens
  • Geert Lycklama
  • Frederik Barkhof
چکیده

BACKGROUND AND PURPOSE The criteria of the National Institute of Neurological Disorders and Stroke (NINDS)-Association Internationale pour la Recherche et l'Enseignement en Neurosciences (AIREN) include thalamic lesions for the diagnosis of vascular dementia (VaD). Although studies concerning VaD and brain aging advocate the use of fluid-attenuated inversion recovery (FLAIR) or T2-weighted images (T2-WI) to detect ischemic lesions, none compared the sensitivity of these sequences to depict thalamic lesions. METHODS We performed a blinded review of T2-WI and FLAIR images in 73 patients fulfilling the radiological part of the NINDS-AIREN criteria (mean age, 71 years; range, 49 to 83 years). This sample was drawn from a large multicenter trial on VaD and was expected to have a high prevalence of thalamic lesions. In a side-by-side review, including T1-weighted images as well, lesions were classified according to presumed underlying pathology. RESULTS The total number of thalamic lesions was 214. Two hundred eight (97%) were detected on T2-WI, but only 117 (55%) were detected on FLAIR (chi(2)=5.1; P<0.05). Although the mean size of lesions detected on T2-WI and not on FLAIR (4.4 mm) was significantly lower than the mean size of lesions detected on both sequences (6.7 mm) (P<0.001), 5 of the 29 lesions >10 mm on T2-WI were not visible on FLAIR. FLAIR detected only 81 (51%) of the 158 probable ischemic lesions and 30 (60%) of the 50 probable microbleeds. CONCLUSIONS FLAIR should not be used as the only T2-weighted sequence to detect thalamic lesions in patients suspected of having VaD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion-weighted and fluid-attenuated inversion recovery imaging in Creutzfeldt-Jakob disease: high sensitivity and specificity for diagnosis.

BACKGROUND AND PURPOSE Abnormalities on diffusion-weighted images (DWIs) and fluid-attenuated inversion recovery (FLAIR) images are reported in Creutzfeldt-Jakob disease (CJD). To our knowledge, no large study has been conducted to determine the sensitivity and specificity of DWI and FLAIR imaging for diagnosing CJD. METHODS Two neuroradiologists, blinded to diagnosis, retrospectively evaluat...

متن کامل

T1-weighted fluid-attenuated inversion recovery at low field strength: a viable alternative for T1-weighted intracranial imaging.

BACKGROUND AND PURPOSE T1-weighted spin-echo imaging has been widely used to study anatomic detail and abnormalities of the brain; however, the image contrast of this technique is often poor, especially at low field strengths. We tested a new pulse sequence, T1-weighted fluid-attenuated inversion recovery (FLAIR), which provides good contrast between lesions, surrounding edematous tissue, and n...

متن کامل

The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.

PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...

متن کامل

Double inversion recovery brain imaging at 3T: diagnostic value in the detection of multiple sclerosis lesions.

BACKGROUND AND PURPOSE To prospectively determine the sensitivity in the detection of multiple sclerosis (MS) lesions by using double inversion recovery (DIR), fluid-attenuated inversion recovery (FLAIR), and T2-weighted turbo spin-echo (T2 TSE) MR imaging at 3T. METHODS Seventeen patients presenting with a clinically isolated syndrome (CIS) suggestive of MS, 9 patients with definite MS, and ...

متن کامل

Magnetic resonance imaging in partial epilepsy: additional abnormalities shown with the fluid attenuated inversion recovery (FLAIR) pulse sequence.

Thirty six patients with a history of partial epilepsy had MRI of the brain performed with conventional T1 and T2 weighted pulse sequences as well as the fluid attenuated inversion recovery (FLAIR) sequence. Abnormalities were found in 20 cases (56%), in whom there were 25 lesions or groups of lesions. Twenty four of these lesions were more conspicuous with the FLAIR sequence than with any of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2004