Repair of damaged supraglottic airway devices: A novel method

نویسندگان

  • Manpreet Singh
  • Ritu Bharti
  • Dheeraj Kapoor
چکیده

Damage of laryngeal mask airway and other supraglottic airway devices has always been a matter of concern. Although manufacturer recommends maximum 40 uses of LMA (and its congeners) but damage before 40 uses needs to be evaluated. We hereby, describe a novel method of repair of supraglottic devices when damage occurs at mask inflation line or pilot balloon valve assembly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

A New Method for Removal of Supraglottic Leech Infestation, an Unusual Cause of Hemoptysis.

Foreign bodies in upper airway may have various presentations and be life threatening. Leeches can attach to upper airway and cause serious problems. Herein we report a 55-year-old man with hemoptysis due to attachment of leech and explain our technique for its removal.

متن کامل

Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.

We evaluated the performance of four currently available manikins: Airway Management Trainer (Ambu, UK), Airway Trainer (Laerdal, Norway), Airsim (Trucorp, Ireland), 'Bill 1' (VBM, Germany), with eight supraglottic airway devices: Airway Management Device, Cobra Perilaryngeal Airway, Combitube, i-Gel, Laryngeal Tube, Laryngeal Tube Disposable, Laryngeal Tube Suction II and Streamlined Liner of ...

متن کامل

Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis

Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis....

متن کامل

Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin

INTRODUCTION Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to operate supraglottic airway devices after a brief training session. METHODS Four different supragl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2010