The fate of Hancock II porcine valve recipients 25 years after implant.

نویسندگان

  • Carlo Valfrè
  • Paolo Ius
  • Giuseppe Minniti
  • Loris Salvador
  • Tomaso Bottio
  • Francesco Cesari
  • Giulio Rizzoli
  • Gino Gerosa
چکیده

OBJECTIVE The Hancock II (HII) is a second-generation porcine bioprosthesis introduced into clinical use in 1982. This study aimed to evaluate very long-term outcomes for the HII valve in a large patient population. METHODS Between May 1983 and November 1993, 517 consecutive patients (pts) (309 male, mean age: 64+/-9 years) underwent valve replacement (VR) surgery with HII, with 302 (58.4%) in the aortic VR (AVR) and 215 (41.6%) in the mitral VR (MVR) position, respectively. At implant, 106 pts (20.5%) were <60 years of age (G1), while 411 (79.5%) were > or =60 years of age (G2). The 25-year follow-up was complete for all pts at a median of 12 years (range: 0-25). RESULTS Long-term death occurred in 208 AVR and in 165 MVR pts. Survival at 15 and 20 years was 39.5% and 23.3% in AVR pts and 39.0% and 15.8% in MVR pts. At 25 years the survival of MVR pts was 13.7% (four pts at risk). Late freedom from re-operation was 85.5% and 79.3% at 15 and 20 years in the AVR pts and 73.3% and 52.8% in the MVR pts, respectively. In the AVR population, 20-year freedom from re-operation was 52.2% in G1 pts and 86.8% in G2 pts (p<0.0001), while in the MVR population it was 41.4% in G1 pts and 61.9% in G2 pts (p=0.201), respectively. CONCLUSIONS These results confirm the excellent long-term performance of the HII bioprosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic valve replacement with stentless and stented porcine valves: a case-match study.

OBJECTIVES To assess the potential benefits of the hemodynamic superiority of stentless valves, we conducted a case-match study among patients who underwent aortic valve replacement with two types of porcine bioprostheses: the Toronto SPV and the stented Hancock II bioprosthesis. METHODS Preoperative clinical variables predictive of death after aortic valve replacement were determined by a st...

متن کامل

Twenty-five year experience with the St. Jude medical mechanical valve prosthesis.

BACKGROUND We evaluated all adult St. Jude mechanical valve recipients at our institution since the initial implant in January 1979 and now present our 25-year experience. METHODS Nine hundred forty-five valve recipients were followed prospectively at 12-month intervals from January 1979 to December 2007. RESULTS Operative mortality was 3% in the aortic valve recipients and 5% in the mitral...

متن کامل

Hemodynamics after surgical repair with right ventricle to pulmonary artery conduit.

To assess the results of cardiac repair utilizing a right ventricular to pulmonary artery conduit, we reviewed postoperative hemodynamic data in 16 patients catheterized 0.5 to 5 years after repair. In 12 patients, a Hancock conduit (dacron conduit with porcine valve) was used; the conduit in the remaining four patients was made with an aortic homograft. All patients in whom an aortic homograft...

متن کامل

Exercise Hemodynamics and Quality of Life after Aortic Valve Replacement for Aortic Stenosis in the Elderly Using the Hancock II Bioprosthesis

Background and Aim. While aortic valve replacement for aortic stenosis can be performed safely in elderly patients, there is a need for hemodynamic and quality of life evaluation to determine the value of aortic valve replacement in older patients who may have age-related activity limitation. Materials and Methods. We conducted a prospective evaluation of patients who underwent aortic valve rep...

متن کامل

Risk factors for the development of prosthetic valve endocarditis.

Risk factors for the development of prosthetic valve endocarditis (PVE) were analyzed in 2642 patients undergoing initial valve replacement at the Massachusetts General Hospital from 1975 to 1982. Follow-up was available for 2608 patients (98.7%); the mean length of follow-up was 39.8 months. PVE developed in 116 patients (4.4%). The actuarial risk of PVE was 3.1% at 12 months and 5.7% at 60 mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2010