Automatic Cobb angle determination from radiographic images.
نویسندگان
چکیده
STUDY DESIGN Automatic measurement of Cobb angle in patients with scoliosis. OBJECTIVE To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. SUMMARY OF BACKGROUND DATA Thirty-six frontal radiographical images of patients with scoliosis. METHODS A modified charged particle model is used to determine the curvature on radiographical spinal images. Three curve fitting methods, piece-wise linear, splines, and polynomials, each with 3 variants were used and evaluated for the best fit. The Cobb angle was calculated out of these curve fit lines and compared with a manually determined Cobb angle. The best-automated method is determined on the basis of the lowest mean absolute error and standard deviation, and the highest R2. RESULTS The error of the manual Cobb angle determination among the 3 observers, determined as the mean of the standard deviations of all sets of measurements, was 3.37°. For the automatic method, the best piece-wise linear method is the 3-segments method. The best spline method is the 10-steps method. The best polynomial method is poly 6. Overall, the best automatic methods are the piece-wise linear method using 3 segments and the polynomial method using poly 6, with a mean absolute error of 4,26° and 3,91° a standard deviation of 3,44° and 3,60°, and a R2 of 0.9124 and 0.9175. The standard measurement error is significantly lower than the upper bound found in the literature (11.8°). CONCLUSION The automatic Cobb angle method seemed to be better than the manual methods described in the literature. The piece-wise linear method using 3 segments and the polynomial method using poly 6 yield the 2 best results because the mean absolute error, standard deviation, and R2 are the best of all methods. LEVEL OF EVIDENCE 3.
منابع مشابه
A Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...
متن کاملComputer-assisted algorithms improve reliability of King classification and Cobb angle measurement of scoliosis.
STUDY DESIGN Interobserver and intraobserver reliability study of improved method to evaluate radiographs of patients with scoliosis. OBJECTIVE To determine the reliability of a computer-assisted measurement protocol for evaluating Cobb angle and King et al classification. SUMMARY OF BACKGROUND DATA Evaluation of scoliosis radiographs is inherently unreliable because of technical and human ...
متن کاملA reliability and validity study for Scolioscan: a radiation-free scoliosis assessment system using 3D ultrasound imaging
BACKGROUND Radiographic evaluation for patients with scoliosis using Cobb method is the current gold standard, but radiography has radiation hazards. Several groups have recently demonstrated the feasibility of using 3D ultrasound for the evaluation of scoliosis. Ultrasound imaging is radiation-free, comparatively more accessible, and inexpensive. However, a reliable and valid 3D ultrasound sys...
متن کاملAutomatic Cobb Angle Measurement System by Using Nuclear Medicine Whole Body Bone Scan
Evaluation of scoliosis is performed traditionally by means of standing posterior-anterior radiographs of the full spine to assess lateral curvature with the Cobb method. In this paper, we present a new automatic algorithm to measure Cobb angle by using nuclear medicine whole body bone scan images. Our algorithm design is based on the fuzzy sets histogram thresholding, anatomical knowledge-base...
متن کاملReliability of radiographic parameters in neuromuscular scoliosis.
STUDY DESIGN Retrospective review of radiographic data. OBJECTIVES This study sought to define interobserver and intraobserver variability to further delineate reliable means by which radiographs of patients with neuromuscular scoliosis can be examined. SUMMARY OF BACKGROUND DATA Previous studies analyzed the use of Cobb angles in the measurement of idiopathic and congenital scoliosis, but ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spine
دوره 38 20 شماره
صفحات -