Development of A Novel Image Guidance Alternative for Patient Localization using Topographic Images for TomoTherapy X Sharon Qi, Benjamin White and Daniel A Low First European Workshop on Monte Carlo Treatment Planning
نویسندگان
چکیده
Helical TomoTherapy(HT) planning depends on optimize parameters including field width (FW), pitch factor (PF) and modulation factor (MF). These optimize parameters are effect to quality of plans and treatment time. The aim of this study was to find the optimized parameters which compromise between plan quality and treatment times. Six nasopharyngeal cancer patients were used. For each patient data set, 18 treatment plans consisted of different optimize parameters combination (FW=5.0, 2.5, 1.0 cm; PF=0.43, 0.287, 0.215; MF2.0, 3.0) were created. The identical optimization procedure followed ICRU83 recommendations. The average D50 of both parotid glands and treatment times per fraction were compared for all plans. The study show treatment plan with FW1.0 cm showed the lowest average D50 of both parotid glands. The treatment time increased inversely to FW. The FW1.0 cm the average treatment time was 4 times longer than FW5.0 cm. PF was very little influence on the average D50 of both parotid glands. Finally, MF increased from 2.0 to 3.0 the average D50 of both parotid glands was slightly decreased. However, the average treatment time was increased 22.28%. For routine nasopharyngeal cancer patients with HT, we suggest the planning optimization parameters consist of FW=5.0 cm, PF=0.43 and MF=2.0.
منابع مشابه
Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in S...
متن کاملLocalization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation
Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...
متن کاملAbstractID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT
ID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT Purpose: To evaluate the potential for Co-60 based tomotherapy including dose delivery and mega-voltage CT (MVCT). Tomotherapy is a rotational implementation of IMRT that provides highly conformal doses and patient setup verification using MVCT. Current tomotherapy is limited to linear accelerators. This poster present...
متن کاملThorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
متن کاملBremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کامل