Clinical Application of a New Dental Reference System for Computer Assisted Surgery at the Lateral Skull Base
نویسندگان
چکیده
Objective: The safest method for a reliable registration on the lateral skull base is the placement of fiducial markers into the patient’s bone by screws. An alternative method is the use of a resin splint that is fixated to the maxillary dentition, which carries the fiducial markers. Then the invasive fixation using bone screws becomes unnecessary. The aim of this study was to evaluate the accuracy of a new dental reference array (DRA). Methods: The DRA was initially tested in laboratory settings and was then applied to ten patients with surgery on the lateral skull base. An individual formed maxillary dental splint was created out of polymethylmethacrylate. The Vector Vision compact® (BrainLAB, Germany) navigation system measured the deviation on several target markers at the lateral skull base in one phantom trial, one cadaver skull and ten patients. Results: The DRA was perfectly adjusted to the phantom. The average deviation was only 0.5mm. The average deviation on four different target markers in the cadaver trial was 0.6 mm. In five patients the accuracy was acceptable (<1.2mm). But in the other five cases the deviation was more than 10mm due to different problems which were analysed carefully. Discussion: The DRA could resolve the problem of invasive marker fixation with little additional effort and cost. However, the successful use depends on the individually formed dental splint, which has to be perfectly adjusted to the maxilla, because the additional weight of the extraoral part acts as a lever and may dislocate. It is essential that the splint does not cant; the reference extension must not graze the skin of the patient; during surgery no coverage should pull on the DRA, otherwise the repositioning is not accurate. When avoiding all this, the accuracy of the dental reference array is sufficient for image-guided surgery of the lateral skull base.
منابع مشابه
Use of bone anchoring device in electromagnetic computer-assisted navigation in lateral skull base surgery.
CONCLUSION The use of the bone anchoring device associated with a fiducial marker, both fixed close to the operating field, improves the reproducibility and effectiveness of the computer-assisted navigation in lateral skull base surgery. OBJECTIVES Computer-assisted navigation in lateral skull base surgery using the electromagnetic system Digipointeur(®) needs an external fiducial marker (tit...
متن کاملEvaluation of Registration strategies for the application of the fiagon navigation system at the lateral skull base
Background: The aim of this study was to evaluate a new navigation system (fiagon GmbH) on the lateral skull base, since prior clinical practice has been limited to the paranasal sinuses. Material and Methods: We performed repeated measurements and registrations on titanium screws, which were attached to specific anatomical locations on five temporal bone specimens. The focus of the investigati...
متن کاملBeyond the middle ear: endoscopic surgical anatomy and approaches to inner ear and lateral skull base.
Currently, the main application of endoscopic surgery relies on the middle ear cholesteatoma surgical treatment. However, in the natural evolution of the technique there are the steps toward of lateral skull base surgery and treatment of pathologic conditions of pertous bone. The endoscopic approaches to lateral skull base are (1) a transcanal exclusively endoscopic approach or (2) combined app...
متن کاملQuality Assurance of Multiport Image-Guided Minimally Invasive Surgery at the Lateral Skull Base
For multiport image-guided minimally invasive surgery at the lateral skull base a quality management is necessary to avoid the damage of closely spaced critical neurovascular structures. So far there is no standardized method applicable independently from the surgery. Therefore, we adapt a quality management method, the quality gates (QG), which is well established in, for example, the automoti...
متن کاملUltrasound A - Mode Based Registration in Computer Aided Surgery of the Skull
Objective: To evaluate the integration of ultrasound Amplitude (A)-mode based surface matching for non-invasive registration of the head into a frameless computer aided surgery system for Oto-Rhinology and Skull Base Surgery, and its accuracy. Design: Experimental study and case series. Setting: Academic medical center. Patients: Twelve patients underwent anterior/para-nasal skull base surgery ...
متن کامل