Membrane sensors for the selective determination of thiopental.

نویسندگان

  • Nashwa M H Rizk
  • Abdel-Hameed M Othman
چکیده

Novel miniaturized polyurethane (PU) membrane sensors in an all-solid state graphite support were developed, electrochemically evaluated and used for the assay of thiopental drug. The thiopental (T) sensors are based on the formation of ion-association complexes of thiopental with copper(II) and cobalt(II)-bathophenanthroline (bphen) counter anions as electroactive materials dispersed in a polyurethane matrix. The sensors show a linear response for thiopental over the range of 1 x 10(-1) - 5 x 10(-5) M thiopental at 25 degrees C over the pH range 6 - 11 with anionic slopes of -28.7 and -28.3 mV decade(-1) with Cu- and Co-bphen thiopental membrane sensors, respectively. These sensors exhibit a fast response time (25 - 45 s), a low detection limit (5 x 10(-6) M), a long lifetime (7 weeks) and good stability. The selectivity coefficients for thiopental sensors relative to the number of interfering anions, were investigated. These sensors were used for the direct potentiometry of thiopental in a pharmaceutical formulation and human serum. Results with mean accuracy of 99.8 +/- 0.5% of nominal were obtained, which compare well with data obtained using spectrophotometric (UV-Vis) and British Pharmacopoeia (BP) methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...

متن کامل

Thiopental and Phenytoin as Novel Ionophores for Potentiometric Determination of Lead (II) Ions

Two novel polymeric membrane sensors for the analysis of Pb(II) have been developed based on two therapeutic drugs, thiopental (TP) and phenytoin (PT) as two new ionophores and potassium tetrakis(p-chlorophenyl) borate (KTpClPB) as a lipophilic additive, in plasticized PVC membranes. The sensors show a Nernstian response for Pb(II) ions over the wide concentration ranges of 1×10(-2) - 7×10(-6) ...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2005