Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

نویسندگان

  • Timolaos Rizos
  • Janina Güntner
  • Ekkehart Jenetzky
  • Lars Marquardt
  • Christine Reichardt
  • Rüdiger Becker
  • Roland Reinhardt
  • Thomas Hepp
  • Paulus Kirchhof
  • Elena Aleynichenko
  • Peter Ringleb
  • Werner Hacke
  • Roland Veltkamp
چکیده

BACKGROUND AND PURPOSE Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxAF detection. METHODS Patients with acute ischemic stroke or transient ischemic attack were prospectively enrolled. After a 12-channel ECG on admission, all patients received 24-hour Holter ECG and CEM. Additionally, ECG monitoring data underwent automated analysis using dedicated software to identify pxAF. Patients with a history of atrial fibrillation or with atrial fibrillation on the admission ECG were excluded. RESULTS Four hundred ninety-six patients (median age, 69 years; 61.5% male) fulfilled all inclusion criteria (ischemic stroke: 80.4%; transient ischemic attack: 19.6%). Median stroke unit stay lasted 88.8 hours (interquartile range, 65.0-122.0). ECG data for automated CEM analysis were available for a median time of 64.0 hours (43.0-89.8). Paroxysmal AF was documented in 41 of 496 patients (8.3%). Of these, Holter detected pxAF in 34.1%; CEM in 65.9%; and automated CEM in 92.7%. CEM and automated CEM detected significantly more patients with pxAF than Holter (P<0.001), and automated CEM detected more patients than CEM (P<0.001). CONCLUSIONS Automated analysis of CEM improves pxAF detection in patients with stroke on stroke units compared with 24-hour Holter ECG. The comparative usefulness of prolonged or repetitive Holter ECG recordings requires further evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced detection of paroxysmal atrial fibrillation by early and prolonged continuous holter monitoring in patients with cerebral ischemia presenting in sinus rhythm.

BACKGROUND AND PURPOSE Diagnosis of paroxysmal atrial fibrillation is difficult but highly relevant in patients presenting with cerebral ischemia yet free from atrial fibrillation on admission. Early initiation and prolongation of continuous Holter monitoring may improve diagnostic yield compared with the standard of care including a 24-hour Holter recording. METHODS In the observational Find...

متن کامل

Response to letter regarding article, "Embolic stroke of undetermined source in the athens stroke registry: a descriptive analysis".

As it is mentioned in our article, 142 (51.6%) patients with Embolic Stroke of Undetermined Source (ESUS) had a 24-hour ambulatory Holter monitoring, whereas 195 (70.9%) ESUS patients had continuous electrocardiographic (ECG) monitoring for 1 week or until discharge from the stroke unit. For the latter patients, continuous ECG monitoring was observed by the trained nurse personnel of the acute ...

متن کامل

Detection of paroxysmal atrial fibrillation in acute stroke patients.

BACKGROUND Atrial fibrillation (AF) is a frequent cause of stroke, but detecting paroxysmal AF (pAF) poses a challenge. We investigated whether continuous bedside ECG monitoring in a stroke unit detects pAF more sensitively than 24-hour Holter ECG, and tested whether examining RR interval dynamics on short-term ECG recordings using an automated screening algorithm (ASA) for pAF detection is a u...

متن کامل

Serial electrocardiographic assessments significantly improve detection of atrial fibrillation 2.6-fold in patients with acute stroke.

BACKGROUND AND PURPOSE Previous studies have reported a low, approximately 1% to 3%, rate of detection of occult atrial fibrillation (AF) with Holter monitor in patients with acute stroke. Furthermore, at least one study has reported that Holter monitoring could not always corroborate initial electrocardiographic (ECG) detection of AF suggesting underestimation of AF by Holter. We compare the d...

متن کامل

Utility of Duranta, a wireless patch-type electrocardiographic monitoring system developed in Japan, in detecting covert atrial fibrillation in patients with cryptogenic stroke

RATIONALE Subcutaneous implantable electrocardiographs are highly effective in detecting covert atrial fibrillation (AF) in cryptogenic stroke. However, these invasive devices are not indicated for all cryptogenic stroke patients, and noninvasive improvements over conventional Holter-type ambulatory electrocardiography are needed. We evaluated the clinical application and effectiveness of Duran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 43 10  شماره 

صفحات  -

تاریخ انتشار 2012