In vivo nanoparticle assessment of pathological endothelium predicts the development of inflow stenosis in murine arteriovenous fistula.

نویسندگان

  • Jie Cui
  • Chase W Kessinger
  • Jason R McCarthy
  • David E Sosnovik
  • Peter Libby
  • Ravi I Thadhani
  • Farouc A Jaffer
چکیده

OBJECTIVE In vivo assessment of pathological endothelium within arteriovenous fistula (AVF) could provide new insights into inflow stenosis, a common cause of AVF primary failure in end-stage renal disease patients. Here we developed nanoparticle-based imaging strategies to assess pathological endothelium in vivo and elucidate its relationship to neointimal hyperplasia formation in AVF. APPROACH AND RESULTS Jugular-carotid AVFs were created in C57BL/6 mice (n=38). Pathological endothelium in the AVF was visualized and quantified in vivo using dextranated magnetofluorescent nanoparticles (CLIO-VT680 [cross-linked iron oxide-VivoTag680]). At day 14, CLIO-VT680 was deposited in AVF, but only minimally in sham-operated arteries. Transmission electron microscopy revealed that CLIO-VT680 resided within endothelial cells and in the intimal extracellular space. Endothelial cells of AVF, but not control arteries, expressed vascular cell adhesion molecule-1 and showed augmented endothelial permeability near the anastomosis. Intravital microscopy demonstrated that CLIO-VT680 deposited most intensely near the AVF anastomosis (P<0.0001). The day 14 intravital microscopy CLIO-VT680 signal predicted the subsequent site and magnitude of AVF neointimal hyperplasia at day 42 (r=0.58, P<0.05). CLIO-VT680 deposition in AVF was further visualized by ex vivo MRI. CONCLUSIONS AVF develop a pathological endothelial response that can be assessed in vivo via nanoparticle-enhanced imaging. AVF endothelium is activated and exhibits augmented permeability, offering a targeting mechanism for nanoparticle deposition and retention in pathological endothelium. The in vivo AVF nanoparticle signal identified and predicted subsequent inflow neointimal hyperplasia. This approach could be used to test therapeutic interventions aiming to restore endothelial health and to decrease early AVF failure caused by inflow stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of arteriovenous fistula stenosis and failure via in vivo inflammation and fibrin molecular imaging

Dialysis Access is the “lifeline” for 1.5 million end-stage renal disease (ESRD) patients across the world. Effective hemodialysis treatment requires reliable large caliber vascular access. The preferred hemodialysis access is an arteriovenous fistula (AVF) because of its lower infection rate, lower hospitalization rate and relatively longer longevity compared to grafts.(1, 2) However, the prim...

متن کامل

Prediction of arteriovenous fistula stenosis and failure via in vivo inflammation and fibrin molecular imaging

Dialysis Access is the “lifeline” for 1.5 million end-stage renal disease (ESRD) patients across the world. Effective hemodialysis treatment requires reliable large caliber vascular access. The preferred hemodialysis access is an arteriovenous fistula (AVF) because of its lower infection rate, lower hospitalization rate and relatively longer longevity compared to grafts.(1, 2) However, the prim...

متن کامل

The experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report

Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period. Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermansh...

متن کامل

Data Mining Performance in Identifying the Risk Factors of Early Arteriovenous Fistula Failure in Hemodialysis Patients

Background and Objectives: Arteriovenous fistula is a popular vascular access method for surgical treatment of hemodialysis patients. The method, however, is associated with a high rate of early failure varying in the range of 20-60%. Predicting early Arteriovenous fistula failure and its risk factors can help reduce its incidence, its hospitalization rate, and associated costs. In this study, ...

متن کامل

برآورد عوامل موثر در شکست فیستول های شریانی-وریدی در بیماران همو دیالیزی مراجعه کننده به بیمارستان هاشمی نژاد با استفاده از مدل رگرسیونی درختی

Background: Hemodialysis is the sole way for management of patients with End Stage Renal Disorders (ESRD). Nowadays, inserting arteriovenous fistula is one of the most common methods for effective hemodialysis. Several factors have been reported for failure of arteriovenous fistulas such as diabetes, biochemical factors, low hemoglobin and increased level of blood calcium and phosphorus. Decisi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arteriosclerosis, thrombosis, and vascular biology

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2015