Clinical evaluation of the bionic glove.

نویسندگان

  • D Popović
  • A Stojanović
  • A Pjanović
  • S Radosavljević
  • M Popović
  • S Jović
  • D Vulović
چکیده

OBJECTIVE Clinical evaluation of the Bionic Glove, a prototype of a new functional electrical stimulation device designed to improve the function of the paralyzed hand after spinal cord injury. PATIENTS Twelve people with spinal cord injury at C5-C7 who had used the device 6 months or more. SETTING Measurements were made at the Institute "Dr Miroslav Zotović" in Belgrade as a part of a multicenter clinical trial. METHODS Measures include Upper Extremity Function Test, Functional Independence Measure, and Quadriplegia Index of Function. RESULTS The daily use of a Bionic Glove had two major effects: (1) increasing the power grasp; and (2) increasing the range of movements. Active force was significantly greater than passive tenodesis force, as shown in other studies. Most manual tasks improved significantly with the use of the assistive system, as judged by the time needed to complete a task or the subject's qualitative ratings of a task difficulty. Most subjects who retained some dexterity without the assistive system hesitated to use the assistive system to manipulate small objects. CONCLUSION The Bionic Glove can significantly improve independence in people with C5-C7 spinal cord injury if their initial Functional Independence Measure and Quadriplegia Index of Function scores are 20% to 50% of the maximum values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset

Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-inv...

متن کامل

Designing and Creating a Virtual Reality Environment and a Wearable Glove with Control and Evaluation Capability to Rehabilitate Patients

Introduction: Using modern technologies like virtual reality in rehabilitation can promise a great movement in medical sciences as sometimes, these technologies shorten the path of reaching the goal. In the present study, a virtual reality environment with the ability of physical interaction was designed to test and measure the hand motion, and a sample of electronic equipment was presented alo...

متن کامل

A Study of the Method of Reconstructing the Bionic Scaffold for Repairing Defective Bone Based on Tissue Engineering

Bionic modeling technology of bone defect repair plays a key role in the process of repairing defective bone based on tissue engineering. In this paper, via studying the structure of bone defect repair, new concept of bionic scaffold is put forward and a new method of integrating medical image processing, 3D reconstruction and CAD technology to construct the bionic scaffold of repairing bone de...

متن کامل

Designing and Creating a Virtual Reality Environment and a Wearable Glove with Control and Evaluation Capability to Rehabilitate Patients

Introduction: Using modern technologies like virtual reality in rehabilitation can promise a great movement in medical sciences as sometimes, these technologies shorten the path of reaching the goal. In the present study, a virtual reality environment with the ability of physical interaction was designed to test and measure the hand motion, and a sample of electronic equipment was presented alo...

متن کامل

Evaluation of Hand Grasping by Instrumented Glove

In this paper the evaluation of effectivenes of instrumented glove in measurement of hand opening and preshaping during reach-to-grasp movement is described. In the experiment presented in this work the reach-to-grasp movement of one healthy subject was measured by two different types of motion-tracking devices (3D optical system, Optotrak, and commercial instrumented glove, 14 sensors Ultra Da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of physical medicine and rehabilitation

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 1999