Assessment of left ventricular function using solid-state gamma camera equipped with a highly-sensitive collimator.

نویسندگان

  • Shin-ichiro Kumita
  • Keiji Tanaka
  • Keiichi Cho
  • Naoki Sato
  • Hidenobu Nakajo
  • Masahiro Toba
  • Yoshimitsu Fukushima
  • Sunao Mizumura
  • Teruo Takano
  • Tatsuo Kumazaki
چکیده

PURPOSE The solid-state gamma camera 2020tc Imager (Digirad, CA) is now commercially available and has been clinically applied. The present study evaluates the feasibility of equilibrium radionuclide ventriculography (ERNV) within a 3 min period using this camera equipped with a highly sensitive collimator. MATERIALS AND METHODS ERNV was performed from the best septal position (left anterior oblique view) in 20 patients with cardiac disease using a single detector anger-type gamma camera equipped with a low-energy, high-resolution collimator. Immediately thereafter, we performed a second ERNV using the solid-state gamma camera equipped with a highly sensitive collimator. Acquisition periods were 10 and 3 min, respectively. RESULTS Significantly more counts were collected from over the left ventricle with the solid-state gamma camera over 3 min than those with the anger-type gamma camera over 10 min (817.1 +/- 387.8 k counts vs. 668.2 +/- 327.4 k counts, p < 0.01). The left ventricular ejection fraction obtained from ERNV data using the solid-state gamma camera correlated closely with those acquired by the anger-type gamma camera (r = 0.94, p < 0.0001, SEE = 5.93%). CONCLUSION The results showed that the solid-state gamma camera could assess left ventricular function with excellent data collection efficiency and high reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimators SPECT/CT device: IQ-SPECT versus conventional protocols in normal subjects

Objective: A novel multifocal collimator, IQ-SPECT (Siemens) consists of cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 (Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging...

متن کامل

Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

متن کامل

Bremsstrahlung imaging from the liver using the Monte Carlo simulation

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2003