A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.
نویسندگان
چکیده
The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40-60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model.
منابع مشابه
Antihypertensive effects of some new nitroxyalkyl 1,4-dihydropyridine derivatives in rat model of two-kidney, one-clip hypertension
Dihydropyridine calcium channel blockers consist one of the widely-used groups of drugs for the management of hypertension. In this study, antihypertensive effects of 5 newly synthesized derivatives of DHP was examined the in rat model of two-kidney, one-clip renal hypertension. The results showed that those compounds containing two nitroxy groups had less decreasing effect on MAP (Men Arterial...
متن کاملAntihypertensive effects of some new nitroxyalkyl 1,4-dihydropyridine derivatives in rat model of two-kidney, one-clip hypertension
Dihydropyridine calcium channel blockers consist one of the widely-used groups of drugs for the management of hypertension. In this study, antihypertensive effects of 5 newly synthesized derivatives of DHP was examined the in rat model of two-kidney, one-clip renal hypertension. The results showed that those compounds containing two nitroxy groups had less decreasing effect on MAP (Men Arterial...
متن کاملبررسی پاسخدهی عروق مزانتر به آنژیوتانسین I و II در خلال ایجاد پرفشاری خون دو کلیه ای گلدبلات و اثر کاپتوپریل بر آن
Essential hypertension is one of the risk factors of cardiovascular diseases. Hypertension etiology is not completely known, it seems that rennin-Angiotensin system has an important role in its etiology, Thus better recognition of this system and its activity changes or vascular reaction changes to different parts of this system during progressive hypertension can be more effective in better re...
متن کاملChronology of blood pressure changes in renal hypertension induced by solid plexiglass clips in the rat
The objective of this study was to determine the chronology of changes in blood pressure in renalhypertension induced by solid plexiglass clips in rats. Saw blades with the thickness of 0.21-0.22 mm wereused to make clips sized 4 × 2 × 2 mm from a piece of 2-mm thick plexiglass. Rats were subjected to shamoperation or left renal arterial clipping, and 1, 2, 3 and 4 weeks later blood pressure, a...
متن کاملبررسی اثر کاپتوپریل بر پاسخدهی عروق مزانتر به آنژیوتانسین I پس از القاء پرفشاری خون کلیوی در موش صحرائی
Changes in tissues and general renin-angiotensin system’s function are the most important factors in cardiovascular disease such as essential hypertension. Recent research shows that general renin - angiotensin system affects the short and immediate response , and that of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 112 3 شماره
صفحات -
تاریخ انتشار 2012