Efficacy of automated continuous positive airway pressure in children with sleep-related breathing disorders in an attended setting.
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to evaluate the safety and efficacy of automated continuous positive airway pressure (Auto-CPAP) in children. Sleep-related breathing disorders (SRBDs) include the clinical spectrum of symptomatic chronic snoring, upper airway resistance syndrome, and obstructive sleep apnea. This spectrum occurs in adults and children. Less data are available for children despite recognition of the condition's prevalence. CPAP has been an established treatment for adults and children. Treatment with Auto-CPAP has been available for adults but has not been reported previously in children. METHODS A group of 14 children (8 months to 12 years old) was evaluated prospectively with baseline polysomnographic study and CPAP titration performed with Auto-CPAP under sleep technologist supervision. RESULTS The results demonstrated that Auto-CPAP is sensitive and effective for children with obstructive sleep apnea in an attended setting. There was 1 subject who did not seem to tolerate Auto-CPAP, but when she was switched to conventional CPAP, she did not tolerate that either. In this subject, the mask never fit well. She was excluded from the analysis. All other patients had a decrease in the number of abnormal breathing events during sleep. The respiratory disturbance index decreased from a mean of 12.6 (SD: 12.4) to 2.6 (SD: 2.7) events per hour. The lowest oxygen saturation improved from a mean of 86% (SD: 10.8) to 93.6% (SD: 3.9). CONCLUSIONS We conclude that Auto-CPAP is safe and effective in an attended environment. Auto-CPAP did not eliminate all the abnormal respiratory events. In subjects 1 and 14, the final respiratory index improved but remained >5 events per hour (5.9 and 7.7, respectively). We suspect that this was because of problems with the masks leaking, which illustrates the importance of follow-up and possible need for retitration in some patients. Proper mask fit is essential for successful treatment. Additional work is needed to evaluate its utility in the home setting. This study was designed to evaluate Auto-CPAP titration in an attended environment. It did not indicate information about the effectiveness in an unattended or home setting. We demonstrate that Auto-CPAP is able to detect abnormal breathing events during sleep in children and may provide the necessary pressure to correct these events. Auto-CPAP can be used safely for pressure titration in an attended setting. Auto-CPAP devices from different manufactures are commercially available for adults. These different devices may have different algorithms and sensitivities to detect abnormal breathing episodes. This study was performed with only 1 specific model of Auto-CPAP. Our results should not be extrapolated to other Auto-CPAP devices without empirical confirmation of the devices' ability to detect and correct events in children. Auto-CPAP can be an alternative treatment for SRBDS in the pediatric population. These results allow for speculation of possible applications for Auto-CPAP in children. A potential advantage of Auto-CPAP includes permitting the initiation of treatment while awaiting a standard CPAP titration. The variable pressure response of Auto-CPAP allows for treatment under different situations such as upper airway infections, different sleeping positions, and changes in weight. As the child grows, the amount of positive pressure needed to maintain airway patency may change. Auto-CPAP may be able to adjust to these changing pressure requirements. Auto-CPAP does not eliminate the need for periodic office visits and evaluations of the clinical course.
منابع مشابه
Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders.
Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBD) including obstructive sleep apnea (OSA). Currently, PAP devices come in three forms: (1) continuous positive airway pressure (CPAP), (2) bilevel positive airway pressure (BPAP), and (3) automatic self-adjusting positive airway pressure (APAP). After a patient is diagnosed with OSA, th...
متن کاملSleep-Disordered Breathing in Children With Metabolic Syndrome: The Role of Leptin and Sympathetic Nervous System Activity and the Effect of Continuous Positive Airway Pressure
OBJECTIVE The purpose of this work was to determine whether, in children with metabolic syndrome and sleep-disordered breathing, metabolic markers separate them from children with metabolic syndrome without sleep-disordered breathing and whether treatment of sleep-disordered breathing with continuous positive airway pressure is associated with an improvement in metabolic derangement. PATIENTS...
متن کاملRisk of traffic accidents in patients with sleep-disordered breathing: reduction with nasal CPAP.
Sleepiness whilst driving constitutes a road safety risk. Sleep-related breathing disorders are the most frequent medical cause of daytime sleepiness, and untreated patients with this condition have been shown to be at a higher risk of having accidents while driving. This study addressed the question of the extent to which treatment of sleep-disordered breathing by nasal continuous positive air...
متن کاملPOSITIVE AIRWAY PRESSURE (PAP) APPLIED THROUGH A NASAL, ORAL, OR AN ORONASAL INTERFACE DURING SLEEP IS THE PREFERRED TREATMENT FOR obstructive
Positive airway pressure (PAP) is used to treat obstructive sleep apnea (OSA), central sleep apnea (CSA), and chronic hypoventilation. This document provides a systematic analysis and grading of peer-reviewed, published clinical studies pertaining to application of PAP treatment in adults. The paper is divided into 5 sections, each addressing a series of questions. The first section deals with ...
متن کاملAuto-adjusting positive airway pressure in children with sickle cell anemia: results of a phase I randomized controlled trial.
Low nocturnal oxygen saturation (SpO(2)) is implicated in complications of Sickle Cell Anemia (SCA). Twenty-four children with SCA were randomized to receive overnight auto-adjusting continuous positive airway pressure (auto-CPAP) with supplemental oxygen, if required, to maintain SpO(2) >or=94% or as controls. We assessed adherence, safety, sleep parameters, cognition and pain. Twelve particip...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pediatrics
دوره 113 5 شماره
صفحات -
تاریخ انتشار 2004