Biomechanical assessment and fatigue characteristics of an articulating nucleus implant

نویسندگان

  • Nathaniel R. Ordway
  • William F. Lavelle
  • Tim Brown
  • Q-Bin Bao
چکیده

BACKGROUND Extrusion is a known complication of lumbar nucleus replacement devices. Despite this fact, this complication has not been well studied in an in vitro cadaveric model under fatigue-loading conditions. METHODS Lumbar constructs (with treated and control levels) were tested in intact, postdisectomy, and postnucleus implant conditions under compression, torsion, and bending for initial biomechanical assessment. Constructs were then tested for 100(k) cycles under fatigue loading to assess extrusion risk. Potential adverse effects to vertebral and endplate fractures were assessed using gross dissection and macroscopic and micro-computed tomography evaluation techniques. RESULTS Based on the initial biomechanical assessment, implantation of the nucleus device significantly increased disc height compared with the discectomy condition, and there were no significant differences between the intact and implanted conditions for range of motion or stiffness. All constructs completed the 100(k) cycles with no extrusions. There was evidence of implant shift toward the right lateral annulus on postfatigue images. Postfatigue dissection and imaging showed no evidence of macroscopic endplate or trabecular fractures. CONCLUSION Using a 2-level lumbar in vitro construct, the biomechanical function of the treated level with an articulating nucleus implant was similar to intact. In vitro fatigue testing showed no implant extrusion and macroscopic changes to the bony structure or cartilaginous endplates when comparing treated and intact levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatigue and corrosion fatigue properties of Ti-6Al-4V implant grade titanium alloy in Ringer solution

Nowadays modification of metallic biomaterials which are used as implants for bone and hard tissues replacement is considered as an important subject. In the current study, corrosion fatigue properties of Ti-6Al-4V alloy investigated via Rotating-Bending standard test method and then, the results compared with the fatigue properties of the specimens tested in the same conditions. Scanning elect...

متن کامل

Nubac Disc Arthroplasty: Preclinical Studies and Preliminary Safety and Efficacy Evaluations

BACKGROUND Disc arthroplasty is gaining popularity for treatment of low-back pain caused by degenerative disc disease (DDD). It can involve total disc replacement or partial disc or nucleus replacement (or augmentation). Compared with total disc replacement, nucleus replacement is less invasive, has less surgical risk, has faster postoperative recovery, and doesn't "burn bridges" should further...

متن کامل

Biomechanical Behavior of a New Nucleus Prosthesis Made of Knitted Titanium Filaments

BACKGROUND One of the greatest challenges in the development of a nucleus prosthesis is to minimize the risk of implant expulsion. At the same time, the physiological flexibility, compressive behavior, and height of the disc should be restored. In this biomechanical in vitro study we investigated the ability of a new nucleus prosthesis made of knitted titanium filaments to meet these challenges...

متن کامل

Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring

BACKGROUND This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. METHODS Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an ...

متن کامل

Nucleus implant parameters significantly change the compressive stiffness of the human lumbar intervertebral disc.

Nucleus replacement by a synthetic material is a recent trend for treatment of lower back pain. Hydrogel nucleus implants were prepared with variations in implant modulus, height, and diameter Human lumbar intervertebral discs (IVDs) were tested in compression for intact, denucleated, and implanted condition. Implantation of nucleus implants with different material and geometric parameters into...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013