Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population.

نویسندگان

  • Guang Sun
  • Curtis R French
  • Glynn R Martin
  • Ban Younghusband
  • Roger C Green
  • Ya-Gang Xie
  • Maria Mathews
  • Jane R Barron
  • Donald G Fitzpatrick
  • Wayne Gulliver
  • Hongwei Zhang
چکیده

BACKGROUND Bioelectrical impedance analysis (BIA) is widely used in clinics and research to measure body composition. However, the results of BIA validation with reference methods are contradictory, and few data are available on the influence of adiposity on the measurement of body composition by BIA. OBJECTIVE The goal was to determine the effects of sex and adiposity on the difference in percentage body fat (%BF) predicted by BIA compared with dual-energy X-ray absorptiometry (DXA). DESIGN A total of 591 healthy subjects were recruited in Newfoundland and Labrador. %BF was predicted by using BIA and was compared with that measured by DXA. Methods agreement was assessed by Pearson's correlation and Bland and Altman analysis. Differences in %BF among groups based on sex and adiposity were analyzed by using one-factor analysis of variance with Bonferroni correction. RESULTS Correlations between BIA and DXA were 0.88 for the whole population, 0.78 for men, and 0.85 for women. The mean %BF determined by BIA (32.89 +/- 8.00%) was significantly lower than that measured by DXA (34.72 +/- 8.66%). The cutoffs were sex specific. BIA overestimated %BF by 3.03% and 4.40% when %BF was <15% in men and <25% in women, respectively, and underestimated %BF by 4.32% and 2.71% when %BF was >25% in men and >33% in women, respectively. CONCLUSIONS BIA is a good alternative for estimating %BF when subjects are within a normal body fat range. BIA tends to overestimate %BF in lean subjects and underestimate %BF in obese subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

. 2 Supplementum 3 2003 Body Composition Assessment with Segmental Multifrequency Bioimpedance Method

Body composition assessment is an important factor in weight management, exercise science and clinical health care. Bioelectrical impedance analysis (BIA) is widely used method for estimating body composition. The purpose of this study was to evaluate segmental multi-frequency bioimpedance method (SMFBIA) in body composition assessment with underwater weighing (UWW) and whole body dual energy x...

متن کامل

New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry.

Malnutrition in patients with severe respiratory insufficiency can lead to severe complications, justifying the use of objective nutritional assessment techniques, such as bioelectrical impedance analysis (BIA), which is an easy, noninvasive method of measuring body composition. The purpose of this study was to develop, and validate against dual-energy X-ray absorptiometry (DXA), a BIA formula ...

متن کامل

Validation of foot-to-foot bioelectrical impedance analysis with dual-energy X-ray absorptiometry in the assessment of body composition in young children: the EarlyBird cohort.

Foot-to-foot bioelectrical impedance analysis (BIA) is simple and non-invasive, making it particularly suitable for use in children. There is insufficient evidence of the validity of foot-to-foot BIA compared with dual-energy X-ray absorptiometry (DEXA) as the criterion method in healthy young children. Our objective was to assess the validity of foot-to-foot BIA against DEXA in a large cohort ...

متن کامل

Relationships among dual-energy X-ray absorptiometry, bioelectrical impedance and ultrasound measurements of body composition of swine

In three separate studies (156 pigs total), dual-energy X-ray absorptiometry (DXA), bioelectrical impedance (BIA) and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body lean mass and ultrasound measurements ...

متن کامل

Estimation of body composition from bioelectrical impedance of body segments: comparison with dual-energy X-ray absorptiometry.

In twenty-eight healthy subjects, ten men and eighteen women, with a range in body mass index (BMI) of 17.9-31.6 kg/m2 and an age range 20-60 years, body composition was estimated by dual-energy X-ray absorptiometry (DEXA), skinfold anthropometry (SFA) and bioelectrical impedance analysis (BIA) of the 'whole body' and body segments. In thirteen subjects muscle mass was also estimated by 24 h ur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 81 1  شماره 

صفحات  -