Results of POLDER in-flight calibration
نویسندگان
چکیده
POLDER is a CNES instrument on board NASDA’s ADEOS polar orbiting satellite, which was successfully launched in August 1996. On October 30, 1996, POLDER entered its nominal acquisition phase and worked perfectly until ADEOS’s early end of service on June 30, 1997. POLDER is a multispectral imaging radiometer/polarimeter designed to collect global and repetitive observations of the solar radiation reflected by the earth/atmosphere system, with a wide field of view (2400 km) and a moderate geometric resolution (6 km). The instrument concept is based on telecentric optics, on a rotating wheel carrying 15 spectral filters and polarizers, and on a bidimensional charge coupled device (CCD) detector array. In addition to the classical measurement and mapping characteristics of a narrow-band imaging radiometer, POLDER has a unique ability to measure polarized reflectances using three polarizers (for three of its eight spectral bands, 443 to 910 nm) and to observe target reflectances from 13 different viewing directions during a single satellite pass. One of POLDER’s original features is that its in-flight radiometric calibration does not rely on any on-board device. Many calibration methods using well-characterized calibration targets have been developed to achieve a very high calibration accuracy. This paper presents the various methods implemented in the in-flight calibration plan and the results obtained during the instrument calibration phase: absolute calibration over molecular scattering, interband calibration over sunglint and clouds, multiangular calibration over deserts and clouds, intercalibration with Ocean Color and Temperature Scanner (OCTS), and water vapor channels calibration over sunglint using meteorological analysis. A brief description of the algorithm and of the performances of each method is given.
منابع مشابه
Results of POLDER in-flight absolute calibration
POLDER is a CNES instrument on-board ADEOS polar orbiting satellite, which was succesfully launched in august 1996. In november 1996, POLDER entered its nominal acquisition phase and functionned perfectly until ADEOS early end of service in june 1997. POLDER is a multispectral imaging radiometer/polarimeter designed to collect global and repetitive observations of the solar radiation reflected ...
متن کاملPARASOL in-flight calibration and performance.
Since 18 December 2004, the PARASOL satellite is a member of the so-called A-train atmospheric orbital observatory, flying together with Aqua, Aura, CALIPSO, CLOUDSAT, and OCO satellites. These satellites combine for the first time a full suite of instruments for observing aerosols and clouds, using passive radiometer complementarily with active lidar and radar sounders. The PARASOL payload is ...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملVicarious calibration of the POLDER ocean color spectral bands using in situ measurements
The radiometric sensitivity of the POLarization and Directionality of the Earth’s Reflectances (POLDER) instrument in the ocean color spectral bands (443, 490, and 565 nm) was checked vicariously by comparing top-of-atmosphere normalized radiances measured by the instrument with those computed for the same geometries using a radiative transfer model. In situ measurements of aerosol optical thic...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Geoscience and Remote Sensing
دوره 37 شماره
صفحات -
تاریخ انتشار 1999