EC DENTAL SCIENCE Case Report An Alternative Implant Impression Technique with Limited Interocclusal Space: Closed-Tray Impression Posts for Open-Tray Impression Technique
نویسنده
چکیده
Accurate impression is a main requirement for obtaining passive fit of restorations. The aim of this case report is an alternative technique in using closed-tray impression posts for open-tray impression technique for exemplification at a patient that can have limited interocclusal vertical space. After osseointegration, 7 implants examined in edentulous maxilla, open-tray impression technique should be used due to angulation and number of implants. Light-cured UDMA material is used for making personal tray. Closed-tray impression posts are inserted and impression is taken with polyether impression material. Impression posts are splinted to tray with light-cured UDMA. Tray is removed from mouth and a model is prepared. Metal-porcelain restorations are prepared conventionally. This case report shows a modified technique that mixes two impression types. This technique can lead to new studies and clinical trials. Further investigations are needed for this technique.
منابع مشابه
تعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالبگیری
Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...
متن کاملComparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants
STATEMENT OF PROBLEM Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. PURPOSE This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. MATERIALS AND METHOD In this experimental study, a steel model with 8...
متن کاملEffect of different impression materials and techniques on the dimensional accuracy of implant definitive casts
BACKGROUND Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. MATERIALS AND METHODS Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxilla...
متن کاملComparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol.
PURPOSE The aim of this in vitro study was to compare the accuracy of two different impression techniques for the All-on-Four implant therapy protocol. MATERIALS AND METHODS An acrylic resin analog for an edentulous maxilla with four internal connection implants (Replace Select, Nobel Biocare) was fabricated according to the All-on-Four protocol. A total of 40 impressions were made with diffe...
متن کاملThree-dimensional accuracy of different impression techniques for dental implants
BACKGROUND Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. MATERIALS AND METHODS Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BI...
متن کامل