Coil Embolization of Wide-Neck Bifurcation Aneurysms Using a Single-Balloon Microcatheter.
نویسندگان
چکیده
BACKGROUND Coil embolization of wide-neck cerebral aneurysms frequently requires stent or balloon assistance. Such approaches to coil embolization increase the procedural complexity, adding risk and cost. OBJECTIVE To describe a series of coil embolization procedures performed using a single-balloon microcatheter to treat wide-neck aneurysms and establish the safety, feasibility and efficacy of this technique. METHODS A retrospective review was performed to identify cases in which the Ascent balloon (Codman Neurovascular, Raynham, Mass., USA) was used as a single-balloon microcatheter for aneurysm coil embolization at two institutions. Clinical, demographic and angiographic data were obtained, and aneurysm volumes as well as packing densities (PD) were calculated. RESULTS Eight cerebral aneurysms were treated using this technique. Six of these were unruptured. The aneurysms had an average neck diameter of 3.7 mm, and the maximum dimension ranged from 5 to 11 mm, with a mean of 7.5 mm. The mean aspect ratio was 2.07. The mean volume of the aneurysms was 180.38 mm(3). The average PD achieved in these 8 aneurysms was 41.79%. Complete occlusion with coil embolization [Raymond-Roy Occlusion Classification (RROC) 1] was achieved in all cases except one, where a small residual was left deliberately and the occlusion grade was RROC 2. There were no intraprocedural complications. CONCLUSION This initial experience demonstrates the feasibility and immediate outcomes of a single-balloon microcatheter technique in coil embolization of wide-neck cerebral aneurysms. This technique may be used to achieve a high PD, comparable to that obtained with stent-assisted coiling or coiling alone, while avoiding permanent stent placement and potentially reducing thromboembolic complications.
منابع مشابه
Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter.
Two types of balloon are usually employed to perform balloon-assisted coil placement in cerebral aneurysms: oval, guide-dependent balloons for sidewall aneurysms and round balloons for bifurcation aneurysms. We report on the use of a new, more compliant, guide-dependent oval balloon microcatheter to seal wide-neck bifurcation aneurysms with coils during endovascular occlusion.
متن کاملEndovascular treatment of wide-neck intracranial aneurysms using a microcatheter protective technique: results and outcomes in 75 aneurysms.
BACKGROUND AND PURPOSE The microcatheter protective technique positions an additional microcatheter in the parent or side-branching artery to protect it during coil embolization. The purpose of this study was to describe this method and to evaluate its efficacy and safety as an alternative to a multiple-microcatheter or balloon- or stent-assisted technique for wide-neck aneurysms. MATERIALS A...
متن کاملHyperForm remodeling-balloon for endovascular treatment of wide-neck intracranial aneurysms.
A new, very compliant remodeling balloon microcatheter has been developed for the treatment of difficult wide-neck intracranial aneurysms (eg, arterial bifurcation or small artery aneurysms). We report selective embolization by the use of the remodeling technique with the HyperForm balloon in 16 consecutive patients with a wide-neck intracranial aneurysm located on an arterial bifurcation or a ...
متن کاملStaged Y-shaped Stent Assisted Coil Embolization in a Wide-Neck Basilar Tip Aneurysm: Case Report
to treat with endovascular embolization. Balloon remodeling and stent-assisted coil embolization have been increasingly available therapeutic strategy in the treatment of these complex lesions (1-3). To our knowledge, there are a few papers that wide-necked basilar bifurcation aneurysms were treated with the Yconfigured dual stent assisted coil embolization (4-6). But all patients were unruptur...
متن کاملY-configured double stent-assisted coil embolization with double microcatheter technique for complex basilar bifurcation aneurysm.
Y-configured double stent technique is useful for coil embolization of a bifurcation wide neck aneurysm while preserving the patency of the two important vessels. However, if the important vessels emanating directly from the aneurysm comprised four vessels, two vessels not deployed, Y-stents might not be preserved with the Y-stent technique by itself. We report a case treated with Y-configured ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interventional neurology
دوره 3 3-4 شماره
صفحات -
تاریخ انتشار 2015