Microleakage of Dual-Cured Adhesive Systems in Class V Composite Resin Restorations

نویسندگان

  • S. Kasraie
  • M. Azarsina
  • Z. Khamverdi
  • F. Shokraneh
چکیده

OBJECTIVE Microleakage is a major factor affecting longevity of composite restorations. This study evaluated the effect of polymerization mode of bonding agent on microleakage of composite restorations. MATERIALS AND METHODS Forty-eight Class V cavities were prepared on buccal and lingual surfaces of 24 extracted human premolars. Occlusal and gingival margins were placed in the enamel and dentin, respectively. Teeth were divided into four groups as follows: Group I: Optibond Solo Plus (light-cured); Group II: Optibond Solo Plus (dual-cured); Group III: Prime & Bond NT (light-cured), Group IV: Prime & Bond NT (dual-cured). Teeth were restored using Z250 composite in three increments. After polishing the restorations, samples were thermocycled for 1000 cycles and stored in distilled water for 3 months. Then they were placed in 2% fuchsine solution for 48 hours. The samples were sectioned longitudinally and evaluated for microleakage under a stereomicroscope at ×40 magnification. Dye penetration was scored on a 0-3 ordinal scale. Data were analyzed using Kruskal-Wallis, Bonferroni and Wilcoxon signed ranks test. RESULTS Microleakage was significantly lower in enamel margins compared to dentin margins (P<0.05); multiple comparisons by Bonferroni tests revealed that the only factor with significant effect on leakage of the restoration is location of the restoration margin. Mode of adhesive polymerization had no significant influence on microleakage (P>0.05). Prime & Bond NT had less microleakage compared to Optibond SoloPlus, but the difference was not significant (P>0.05). CONCLUSION There was no difference in the amount of microleakage in Class V composite restorations using light-cured and dual-cured bonding systems. Dentinal margins of restorations exhibited more microleakage than enamel margins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations.  Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...

متن کامل

Factors contributing to the incompatibility between new adhesive systems and various composite resin restorations

  Factors contributing to the incompatibility between new adhesive systems and various composite resin restorations     Dr. F. Maleknejad* - Dr. H. Moosavi**  *- Associate Professor of Operative Dentistry Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences.  **- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences.   ...

متن کامل

In Vitro Microleakage of Class V Composite Restorations in Use of Three Adhesive Systems

Background and Aim: Microleakage is a drawback of composite restorations and it is more noticeable in dentinal walls. Despite advances in dentin bonding agents, no adhesive can completely eliminate microleakage and provide a hermetic seal. This study aimed to compare microleakage of three resin bonding agents namely a universal adhesive, two-step self-etch system and two-step total-etch system....

متن کامل

Microleakage of Composite Resin Restorations Using a Type of Fifth and Two Types of Seventh Generations of Adhesive Systems: A Comparative Study

Introduction: In recent dentin adhesive systems etching of enamel/dentin are achieved simultaneously. The objective was to evaluate the microleakage of composite restorations using Single Bond2 (5th generation), Clearfil S3 Bond and G Bond (7th generation). Methods: Class V cavities were prepared on  45 extracted intact premolars with gingival margins at the cementoenamel junction and they were...

متن کامل

Effect of Different Base Materials and Techniques on Microleakage in Class II Composite Open Sandwich Restorations

Aims: This study was performed to compare microleakage in class II composite restorations with flowable composites and dual cure composite resin as intermediate material and also to evaluate the effect of delayed light polymerization of dual cure composite base on microleakage. Materials and methods: Class II box cavities were made with air water spray and divided into four groups. Group 1 was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2012