Feasibility of long-term cerebral and peripheral regional tissue oxygen saturation measurements.
نویسندگان
چکیده
The aim of this study was to analyse the feasibility of long-term measurements of cerebral (crSO2) and peripheral (prSO2) regional tissue oxygen saturation on the first day of life by determining the amount of artefacts and their influence on rSO2. Near infrared spectroscopy (NIRS) measurements were performed fronto-parietal left (crSO2) and on the right forearm (prSO2). Arterial oxygen saturation (SpO2) was measured by pulse oximetry on the right wrist. Three criteria (C) were defined to identify artefacts (C1: missing values, C2: rSO2 jumping >15%, C3: rSO2 ≥ SpO2). The number of artefacts as a percentage of measurement time and mean rSO2 was calculated after the introduction of each criterion. Measurements were performed in 40 neonates. The number of artefacts in crSO2 measurements was similar after introduction of C1 (7.37 ± 4.64%) and after introduction of all criteria (8.89 ± 4.59%). The number of artefacts in prSO2 measurements after introduction of C1 was 10.83 ± 4.21%, and after introduction of all criteria significantly higher with 17.78 ± 4.27%. After introduction of C1, further criteria did not significantly change rSO2: crSO2 (78.6 ± 1.3% versus 78.5 ± 1.2%) and prSO2 (83.7 ± 0.9% versus 83.5 ± 0.9%). In conclusion, long-term NIRS measurements of crSO2 and prSO2 are feasible, since most artefacts are due to missing values and therefore easy to recognize.
منابع مشابه
Regional tissue oxygen saturation: comparability and reproducibility of different devices.
UNLABELLED Comparability and reproducibility of different near-infrared spectroscopy devices measuring regional tissue oxygen saturation remain poor. Aim of the present study was to compare values and reproducibility of cerebral∕peripheral "tissue-oxygenation-index" (TOI; NIRO 300, Hamamatsu(®), Japan) with cerebral∕peripheral "regional-oxygen-saturation" (rSO; INVOS5100, Somanetics(®), USA), a...
متن کاملStudy protocol for the PHANTOM study: prehospital assessment of noninvasive tissue oximetry monitoring
BACKGROUND Traumatic brain injury is a major cause of mortality and morbidity worldwide. It can be worsened by secondary injury particularly with hypoxia or hypotension. Current prehospital guidelines emphasise regular measurement of peripheral oxygen saturation and blood pressure but there is no monitor in use to provide direct information relating to blood flow or oxygen delivery to the brain...
متن کاملImpact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies.
BACKGROUND Cerebral oximetry is a noninvasive technology using near-infrared spectroscopy (NIRS) to estimate regional cerebral oxygen saturation. Although NIRS cerebral oximetry is being increasingly used in many clinical settings, interdevice technologic differences suggest potential variation in the ability to accurately acquire brain oxygenation signals. The primary objective of this study w...
متن کاملCerebral oxygenation at high altitude and the response to carbon dioxide, hyperventilation and oxygen. The Birmingham Medical Research Expeditionary Society.
Cerebral oxygenation is likely to be of critical importance in determining function at high altitude. The present study has used the technique of near-IR spectroscopy to monitor changes in cerebral regional oxygenation in response to inhaled carbon dioxide, hyperventilation and supplementary oxygen on ascent to 4680 m over 3 days. At sea level, inhaled CO(2) resulted in a significant rise in ce...
متن کاملRopivacaine decreases tissue oxygen saturation following peripheral nerve block in children
Background: Local anesthetics can cause vasoconstriction and disrupt neuronal impulses, reducing regional blood flow and increasing tissue oxygen consumption. This could alter regional oxygen supply and demand. Because microcirculation modifies during development and oxygen consumption kinetics differ between children and adults, we aimed to assess effects of ropivacaine Peripheral Nerve Block ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 35 7 شماره
صفحات -
تاریخ انتشار 2014