Boosting BOLD fMRI by K-Space Density Weighted Echo Planar Imaging
نویسندگان
چکیده
Functional magnetic resonance imaging (fMRI) has become a powerful and influential method to non-invasively study neuronal brain activity. For this purpose, the blood oxygenation level-dependent (BOLD) effect is most widely used. T2* weighted echo planar imaging (EPI) is BOLD sensitive and the prevailing fMRI acquisition technique. Here, we present an alternative to its standard Cartesian recordings, i.e. k-space density weighted EPI, which is expected to increase the signal-to-noise ratio in fMRI data. Based on in vitro and in vivo pilot measurements, we show that fMRI by k-space density weighted EPI is feasible and that this new acquisition technique in fact boosted spatial and temporal SNR as well as the detection of local fMRI activations. Spatial resolution, spatial response function and echo time were identical for density weighted and conventional Cartesian EPI. The signal-to-noise ratio gain of density weighting can improve activation detection and has the potential to further increase the sensitivity of fMRI investigations.
منابع مشابه
Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملDiffusion-weighted spin-echo fMRI at 9.4 T: microvascular/tissue contribution to BOLD signal changes.
The nature of vascular contribution to blood oxygenation level dependent (BOLD) contrast used in functional MRI (fMRI) is poorly understood. To investigate vascular contributions at an ultrahigh magnetic field of 9.4 T, diffusion-weighted fMRI techniques were used in a rat forepaw stimulation model. Tissue and blood T(2) values were measured to optimize the echo time for fMRI. The T(2) of arter...
متن کاملA novel multi-echo fMRI weighting strategy using principal component analysis for BOLD contrast sensitivity enhancement
Introduction: In functional magnetic resonance imaging (fMRI), acquisition parameters must balance the tradeoffs between spatial coverage and resolution, temporal resolution, and signal contrast. Blood oxygenation level dependent (BOLD) fMRI studies commonly employ a 2D multi-slice T2*-weighted echo-planar imaging (EPI) acquisition to capture changes in T2* decay due to BOLD signal fluctuation,...
متن کاملCorticothalamic modulation during absence seizures in rats: a functional MRI assessment.
PURPOSE Functional magnetic resonance imaging (fMRI) was used to identify areas of brain activation during absence seizures in an awake animal model. METHODS Blood-oxygenation-level-dependent (BOLD) fMRI in the brain was measured by using T2*-weighted echo planar imaging at 4.7 Tesla. BOLD imaging was performed before, during, and after absence seizure induction by using gamma-butyrolactone (...
متن کاملBOLD fMRI using a modified HASTE sequence
For more than a decade, turbo spin echo (TSE) pulse sequences have been suggested as an alternative to echo planar imaging (EPI) sequences for fMRI studies. Recent development in parallel imaging has renewed the interest in developing more robust TSE sequences for fMRI. In this study, a modified half Fourier acquisition single-shot TSE (mHASTE) sequence has been developed with a three-fold GRAP...
متن کامل