Optimization of thermal ghost imaging: high-order correlations vs. background subtraction.

نویسندگان

  • Kam Wai C Chan
  • Malcolm N O'Sullivan
  • Robert W Boyd
چکیده

We compare the performance of high-order thermal ghost imaging with that of conventional (that is, lowest-order) thermal ghost imaging for different data processing methods. Particular attention is given to high-order thermal ghost imaging with background normalization and conventional ghost imaging with background subtraction. The contrast-to-noise ratio (CNR) of the ghost image is used as the figure of merit for the comparison.We find analytically that the CNR of the normalized high-order ghost image is inversely proportional to the square root of the number of transmitting pixels of the object. This scaling law is independent of the exponents used in calculating the high-order correlation and is the same as that of conventional ghost imaging with background subtraction. We find that no data processing procedure performs better than lowest-order ghost imaging with background subtraction. Our results are found to be able to explain the observations of a recent experiment [Chen et al., arXiv:0902.3713v3 [quant-ph]].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the Amenability of Ghost Imaging to Large Parallel Acceleration Factors

Introduction Ghost imaging is a newly proposed methodology for magnetic resonance angiography (MRA) that eliminates the need for image subtraction. Using a 3D pulse sequence that acquires slices outside of the body, the method works by modulating arterial signal to produce ghost artifacts. Arterial ghost artifacts localizing in air outside of the body are then processed and viewed along multipl...

متن کامل

Nature of light correlations in ghost imaging

We investigate the nature of correlations in Gaussian light sources used for ghost imaging. We adopt methods from quantum information theory to distinguish genuinely quantum from classical correlations. Combining a microscopic analysis of speckle-speckle correlations with an effective coarse-grained description of the beams, we show that quantum correlations exist even in 'classical'-like therm...

متن کامل

Highly Accelerated Contrast-Enhanced MR Angiography using Ghost Imaging

Introduction: Contrast-enhanced MRA (CE-MRA) is a well-established methodology that accurately depicts vessel morphology in multiple vascular territories. In order to minimize the signal contribution from background tissues, a precontrast data set is typically subtracted from the post-contrast data set. Parallel acceleration techniques such as GRAPPA and SENSE are routinely used to improve spat...

متن کامل

Multiple attenuation in VSP multiple imaging and primary imaging

Imaging of downgoing first-order free-surface multiples (ghosts) with VSP data can provide a subsurface image with wider coverage, better vertical resolution, and higher-fold than conventional imaging of VSP primary reflections. A problem with VSP downgoing first-order multiple (ghost) imaging is the interference from downgoing high-order multiples, similar to the interference from multiples wh...

متن کامل

Normalized ghost imaging

We present an experimental comparison between different iterative ghost imaging algorithms. Our experimental setup utilizes a spatial light modulator for generating known random light fields to illuminate a partially-transmissive object. We adapt the weighting factor used in the traditional ghost imaging algorithm to account for changes in the efficiency of the generated light field. We show th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2010