Closed Form Optimal Solution of a Tuned Liquid Column Damper Responding to Earthquake
نویسنده
چکیده
In this paper the vibration behaviors of a structure equipped with a tuned liquid column damper (TLCD) under a harmonic type of earthquake loading are studied. However, due to inherent nonlinear liquid damping, it is no doubt that a great deal of computational effort is required to search the optimum parameters of the TLCD, numerically. Therefore by linearization the equation of motion of the single degree of freedom structure equipped with the TLCD, the closed form solutions of the TLCD-structure system are derived. To find the reliability of the analytical method, the results have been compared with other researcher and have good agreement. Further, the effects of optimal design parameters such as length ratio and mass ratio on the performance of the TLCD for controlling the responses of a structure are investigated by using the harmonic type of earthquake excitation. Finally, the Citicorp Center which has a very flexible structure is used as an example to illustrate the design procedure for the TLCD under the earthquake excitation. Keywords—Closed form solution, Earthquake excitation, TLCD.
منابع مشابه
damper responding to earthquake
In this paper the vibration behaviors of a structure equipped with a tuned liquid column damper (TLCD) under a harmonic type of earthquake loading are studied. However, due to inherent nonlinear liquid damping, it is no doubt that a great deal of computational effort is required to search the optimum parameters of the TLCD, numerically. Therefore by linearization the equation of motion of the s...
متن کاملExperimental Study on Using Uniform Tuned Liquid Column Damper for Structural Control of Buildings Resting on Loose Soil
In this study, through series of shaking table tests and statistical analysis, the efficiency of Uniform Tuned Liquid Column Damper (UTLCD) in structures resting on loose soils, considering soil-structure interaction was investigated. The soil beneath the structure is loose sandy soil. The Laminar Shear Box (LSB) as a soil container was adopted and the scaled form of the prototype structure nam...
متن کاملComparative Performance Study of Tuned Liquid Column Ball Damper for Excessive Liquid Displacement on Response Reduction of Structure
The tuned liquid column damper (TLCD) having a uniform cross-sectional tube of U-shaped, occupied with liquid is used as a vibrational response mitigation device. The tuned liquid column ball damper (TLCBD) is a modified TLCD, where, an immovable orifice, positioned at the middle part of the horizontal portion, is replaced by a metal ball. Different studies on the unconstrained optimization per...
متن کاملUpgrading the Seismic Capacity of Pile-Supported Wharfs Using Semi-Active Liquid Column Gas Damper
One of the most important structures in the ports is the wharf. The most common one is the pile-supported wharf. This type of wharf is consisted of a number of piles and one deck which placed on the piles. In addition to the conventional loads that this structure should withstand, in seismic areas, pile-supported wharfs should have the necessary capacity and strength against seismic excitations...
متن کاملOPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS
This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...
متن کامل