Robust design for acetabular cup stability accounting for patient and surgical variability.

نویسندگان

  • Kevin L Ong
  • Thomas J Santner
  • Donald L Bartel
چکیده

The stability of cementless acetabular cups depends on a close fit between the components and reamed acetabular cavities to promote bone ingrowth. Cup performance and stability are affected by both design and environmental (patient-dependent and surgical) factors. This study used a statistically based metamodel to determine the relative influences of design and environmental factors on acetabular cup stability by incorporating a comprehensive set of patient-dependent and surgical variables. Cup designs with 2 mm or 3 mm intended equatorial bone-implant interferences appeared to perform the best, improving implant stability with smaller mean and variability in cup relative motions and greater mean and smaller variability in ingrowth areas. Cup eccentricity was found to have no effect on implant performance. Design variables did not contribute as much to the variation in performance measures compared to the environmental variables, except for potential ingrowth areas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acetabular cup geometry and bone-implant interference have more influence on initial periprosthetic joint space than joint loading and surgical cup insertion.

Environmental variations in patient-dependent and surgical factors were modeled using robust optimization with a finite element acetabular cup-pelvis model. A previously developed statistical optimization scheme was used to: (1) determine the cup geometry and the optimal cup-bone interference that maximized bone-implant contact areas and minimized changes in the gap volume between the implant a...

متن کامل

Acetabular Fractures in the Senior Population– Epidemiology, Mortality and Treatments

Background:Management of acetabular fractures in the senior population can be one of the most challenging injuries tomanage. Furthermore, treating surgeons have a paucity of information to guide the treatment in this patient population.The purpose of this study was to determine: (1) demographic and epidemiologic data, (2) mortality rates for nonoperativecompared to operative management at diffe...

متن کامل

A novel method to assess primary stability of press-fit acetabular cups.

Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stabili...

متن کامل

The Stability of Acetabular Cup under Screw Fixation

INTRODUCTION The total hip replacement is a common surgical procedure in orthopaedics. However, the acetabular cup loosening is one of the major failure modes of cementless acetabular cup. Many researches point out that an unstable cup would induce a large micromotion under dynamic loading. This large micromotion would reduce the bone ongrowth on the cementless cup surface and prohibit the osse...

متن کامل

Acetabular cup position and risk of dislocation in primary total hip arthroplasty

Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 130 3  شماره 

صفحات  -

تاریخ انتشار 2008